42nd AIVC - 10th TightVent - 8th venticool Conference - Rotterdam, Netherlands - 5-6 October 2022

The common demand control approach for MVHR systems using one CO2 sensor within the ventilation unit is assessed based on a typical residential apartment situation using CONTAM models. The simulation results confirm that air flow and therefore fan electricity and ventilation losses can be reduced compared to constant flow control, in particular for higher nominal air exchange rates. However, under certain boundary conditions, e.g. unevenly occupied dwellings indoor air quality in certain rooms may suffer with this DCV strategy.