Dudek S J M, Valentine G
wood frame
condensation
moisture
structural fault
Languages
English
Bibliographic info
8th AIVC Conference "Ventilation technology research and application" Ueberlingen, West Germany, 21-24 September 1987

This paper presents and discusses results of moisture transfer into timber frame constructions. The two mechanisms of transfer are diffusion and bulk air movement. Three defects in construction were monitored punctured vapour barrier, continuous path via an electrical socket and discontinuities at junctions. The study has shown that, under steady-state conditions condensation can take place, while under varying conditions both condensation and evaporation occur. This second case is typical of the building in use, and can prevent high levels of moisture existing in timber components.