Skip to main content
Publi image
Publi data
Hala Hassan, Asit Kumar Mishra, Hilary Cowie, Marie Coggins
Energy Retrofit
indoor air quality
Particulate Matter (PM2.5)
Health Impact Assessment
Languages
English
Pages (count)
4
Bibliographic info
44th AIVC - 12th TightVent - 10th venticool Conference – Dublin, Ireland - 9-10 October 2024

Maintaining good indoor air quality (IAQ) post energy retrofit is essential to ensure the health and wellbeing of building occupants. In this study, a number of indoor air pollutants were measured in a sample of Irish homes pre and post deep energy retrofit (DER). Airborne concentrations of PM2.5 and formaldehyde showed significant increases (p <0.0001) post-retrofit. A health impact assessment was conducted and the results suggest that the greatest health burden (for lung cancer and all-cause mortality) was associated with exposure to PM2.5.