Skip to main content
Publi image
Publi data
Handa K, Gusten J.
wood frame
air infiltration
correlation
detached house
natural ventilation
pressure distribution
theoretical modelling
Languages
English
Bibliographic info
3rd AIVC Conference "Energy efficient domestic ventilation systems for achieving acceptable indoor air quality" London, UK, 20-23 September 1982

Natural and forced ventilation are directly and indirectly influenced by the pressure distribution around a building. Results of full-scale pressure measurements on a typical Swedish timber house are presented. The rate of air infiltration has been calculated by employing the values obtained from full-scale pressure distribution, air leakage characteristics and temperature differences. The results are compared with the actual ventilation obtained from tracer gas measurements. The study shows the inadequacy of the existing calculating model when used in conjunction with full-scale measured data. It seems that further efforts are needed to correlate the experimental and theoretical models.