G. Fragoyiannis, D. Mytakis and F.A. Coutelieris
SOFC
biogas
Power plant
energy
Exergy analysis
Languages
English
Bibliographic info
Proceedings of the 34th AIVC - 3rd TightVent - 2nd Cool Roofs' - 1st venticool Conference , 25-26 September, Athens 2013

Fuel cells are highly efficient energy conversion systems that have recently gained significant interest in terms of both science and applications. Exergy analysis is adopted here for a power plant involving SOFC with external steam reforming that is fuelled by modeled biogas/steam mixtures. The electrical efficiency has been estimated and the effect of various operational parameters on the process efficiency has been investigated. The optimal operation parameters of the integrated SOFC plant are specified by pinpointing and minimizing the existing losses, while a parametric analysis has been also performed to provide guidelines for practical design.