Dick J.B.
air change rate
tracer gas
helium
house
occupancy effects
Languages
English
Bibliographic info
Heat. Pip. Air. Cond. vol. 22 no. 5 p131-137

Outlines ventilation measurements being made on two storey semi-detached houses using helium as a tracer gas. Describes measurement of decay rates in single rooms, the recirculation between two rooms and by summation the ventilation rate of thewhole house. Describes installation used to measure ventilation rates when homes are occupied without interfering with the normallife of tenants.