Skip to main content
Publi data
Keiko Sato, Takashi Kurabuchi, Takeshi Ogasawara, Masaaki Ohba, Shizuo Iwamoto, Nobumi Sahashi and Seigo Ikehara
thermal manikin
convective heat transfer coefficient
thermal resistance of clothing
cross ventilation
PMV calculation
Languages
English
Bibliographic info
The International Journal of Ventilation, Vol. 10 N°2, September 2011

The convective heat transfer coefficient around the human body is important for evaluating the effects that airflows exert on thermal comfort. However measuring it is generally difficult. Therefore, in this research, a thermal manikin was set up inside a wind tunnel simulating a ventilation environment. This was used to measure the convective heat transfer coefficient around the human body and the relationship between the effects of airflows and the thermal resistance of clothing under various clothing conditions. The results showed that the convective heat transfer coefficient near the thermal manikin was somewhat lower than the value obtained with the calculation formula used in the PMV calculation. It was also confirmed that the thermal resistance of clothing decreases due to the effects of airflows in the case of clothing with high permeability, as has been described in previous research.