Skip to main content

Bibliographic database Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

Vorgestellt wird eine kürzlich durchgeführte Studie, bei der eine neuartige Ultraschalltechnologie eingesetzt wurde, um Luftleckagen in Gebäuden aufzuspüren und zu quantifizieren sowie die Luftdichtheit und Luftdurchlässigkeit von Gebäudehüllen und einzelnen Bauteilen zu bewerten...

Daniel Dobrowolski, David Johnston, Angus Hodgkiss

Is there a fast and reliable acoustic method to identify and assess leakages in building envelopes? How well does this method work, are there any challenges and which analyses are used to ensure that it is fit for purpose? We conducted systematic analyses under laboratory conditions and set up a purpose-made airtightness...

Björn Schiricke, Markus Diehl, Johannes Pernpeintner, Alexander Jahnke, Michael Markus Ackermann, Christian Probst, János Grebe

Können Leckagen in der Gebäudehülle mit einer akustischen Methode schnell und zuverlässig geortet und bewertet werden? Wie gut funktioniert das bereits, wo gibt es Schwierigkeiten und welche Untersuchungen werden durchgeführt, um die Methode praxistauglich zu machen?

Björn Schiricke, Markus Diehl, Johannes Pernpeintner, Alexander Jahnke, Michael Markus Ackermann, Christian Probst, János Grebe

Can adequate protection against radon buildup according to §123 of the German Radiation Protection Act (Strahlenschutzgesetz, StrSchG) be verified during airtightness tests with the fan pressurization method? Radon is a noble gas which occurs naturally in the uranium-238 decay chain and as such also decays radioactively...

Marc Ellinger

Radon ist ein Edelgas, das als Folgeprodukt der Uran-238-Zerfallsreihe ebenfalls radioaktiv zerfällt. Das Gas dringt über Undichtheiten/Fehlstellen der erdberührten Gebäudehülle in Gebäude ein und reichert sich dort an. Hierdurch steigt das Risiko für die Nutzer der jeweiligen Gebäude, Bewohner, Arbeitnehmer, aufgrund langandauernder...

Marc Ellinger