Skip to main content

Bibliographic database Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

Ein Teil des AEGIR-Projekts zielt darauf ab, einen digitalen, nachhaltigen Rahmen zu entwickeln, der die Einführung umfassender Sanierungen fördert und nahezu energieneutrale Gebäude ermöglicht. Zu diesem Zweck arbeitet das Fraunhofer ISE an einem Python-basierten Programm, das automatisch optimale Routen...

Sven Auerswald, Seyedehmaedeh Aghili, Olaf Knospe

Is it possible to derive an outside air flow rate from the net air exchange rate nL50 and use it for ventilating dwelling units? We calculated the outside air flow rates via leaks in the envelope area as per standards and matched them with the values from real construction projects. Typically, the outside air flow rate via infiltration is derived...

Oliver Solcher

Kann aus dem Gebäudedichtheitskennwert nL50 ein Außenluftvolumenstrom errechnet werden, der für die Lüftung von Wohnräumen nutzbar ist? Es erfolgte eine Gegenüberstellung der aus Normen errechneten Aussenluftvolumenströme über Undichtheiten in der Hüllfläche und ein Abgleich mit Messwerten aus realen...

Oliver Solcher

As a consultant and operator of Blower Door testing, one often wonders about the durability of materials over a building's lifetime. It is not uncommon to see products where tapes and sealing materials fail after a very short period. This raises the question of whether airtightness can truly be considered a quality parameter...

Lars Due

Als Berater und Ausführender von Blower Door-Tests fragt man sich oft, wie haltbar Materialien über die Lebensdauer eines Gebäudes sind. Es kommt nicht selten vor, dass Dichtungsmate- rialien bereits nach sehr kurzer Zeit versagen. Dies wirft die Frage auf, ob die Luftdichtheit wirk- lich als dauerhaftes Qualitätsmerkmal für...

Lars Due