AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

Weltweit steigt die Nachfrage nach Luftdichtheitsprüfungen von hohen Gebäuden mit einer Höhe ab ca. 100 m. Dieser Bericht informiert über das Planungs- und Messkonzept zur Prüfung des gesamten Gebäudes als „Single-Zone“ und stellt die Ergebnisse und Erkenntnisse der Luftdichtheitsprüfungen vor. Der Prüfaufbau und die Prüfungen...

Stefanie Rolfsmeier

According to the two Swiss building standards Minergie-P and Minergie-A, individual dwelling units are considered measuring zones for airtightness, irrespective of whether they are in a new, renovated or modernized building. The Minergie standards focus on comfort between the dwelling units and the energy losses...

Gregor Notter

Für die beiden schweizerischen Energiestandards Minergie-P und Minergie-A werden bei der Luftdichtheit die einzelnen Nutzeinheiten als Messzonen betrachtet, egal ob Neubau oder Erneuerung / Modernisierung. Im Vordergrund steht der Komfort zwischen den Nutzungseinheiten nebst den energetischen Verlusten durch Infiltration...

Gregor Notter

When dealing with very airtight buildings and buildings with flexible airtight roofing felts it might take several minutes for the differential pressure and air flow to level out after having changed the fan speed. Taking premature readings of the values causes measuring errors. The lecture provides pointers for test teams to avoid such measuring...

Joachim Zeller

Bei sehr dichten Gebäuden und bei Gebäuden mit flexiblen Luftdichtheitsschichten kann es nach dem Verstellen des Ventilators Minuten dauern, bis sich der Differenzdruck und der Volumenstrom praktisch nicht mehr ändern. Zu frühzeitiges Ablesen der Werte führt zu Messfehlern. Der Vortrag gibt Handlungsempfehlungen...

Joachim Zeller