Skip to main content

The 9th AIVC Conference - Effective ventilation, was held in Gent, Belgium, 12-15 September 1988.

Contains 44 papers.

Volume content
9th AIVC Conference: Effective ventilation (Book of Proceedings)

Twenty three papers from the ninth AIVC Conference, titles as follows: Keynote speech: Air Infiltration and Ventilation; Natural airflows between roof,…

AIVC
Ventilation habits in residential buildings.

Experimental investigations concerning energy savings achieved in buildings with passive solar components (e.g. large south-front windows, sunspaces or…

Erhorn H
Ventilation and indoor air quality in a modern office building.

The National Institute of Standards and Technology (formerly the National Bureau of Standards) has through an interagency agreement with the Public Building…

Grot R A, Persily A, Hodgson A T, Daisey J M
Application of mathematical modelling to the evaluation of building ventilation systems.

Numerical modelling is performed for three-dimensional turbulent buoyant flows emerging from an air diffuser in an air-conditioned, ventilated room. The…

Fang J B, Grot R A, Kurabuchi T
Air infiltration and ventilation.

General background to the conference.

Colla M
Extended testing of a multi-family building using constant concentration and PFT methods.

More than two months of detailed test data have been gathered using modified constant concentration tracer gas techniques for a six-storey, 60 apartment,…

Harrje D T, Bohac D L, Feuermann D
Effective ventilation in offices - the occupant's perspective.

Air quality and draught avoidance are fairly important to office staff; consequently, the occupant's perspective should be taken into account when assessing…

Griffiths I D, Huber J W, Baillie A P
A study of the ventilation characteristics of a suspended floor

The ventilation and leakage characteristics of suspended floors are not well documented. As part of a larger study of air flows in housing, the air flow…

Lilly J P, Piggins J M, Stanway R J
Determination of ventilation efficiency based upon short term tests.

In this paper a short term testing methodology is developed to evaluate the performance of ventilation systems with respect to control of indoor air…

Anderson R
Recirculation of air in dwellings. Differences in concentration between rooms in dwellings due to the ventilation system.

The Dutch Standard NEN 1087 "Ventilation of dwellings": Requirements (1) is at this moment under review. A requirement can be found about the quality of air…

De Gids W F, Phaff J C
A numerical study of buoyancy-driven flows of mass and energy in a stairwell.

This paper describes a two-dimensional numerical study, by finite-volume method of buoyancy-driven flow in a half-scale model of a stairwell. The stairwell…

Zohrabian A S, Mokhtarzadieh-Dehghan M R
Flow conditions in a mechanically ventilated room with a convective heat source.

The ventilation of a test room (LxWxH = 5.4x3.6x2.4 m) with a wall mounted heat source is investigated for two different air terminal devices. The…

Heiselberg P, Nielsen P V
The use of a guarded zone pressurization technique to measure air flow permeabilities of a multizone building.

In the past few years, research efforts have been made to acquire accurate knowledge about infiltration and ventilation in multi-zone buildings. By this way…

Furbringer J M, Roecker C, Roulet C A
A simplified approach of air infiltration in multizone buildings.

The specific value of different flows resulting from air exchanges between rooms or with the outside is not always important. An extensive model is not…

Caccavelli D, Roux J J, Allard F
Natural ventilation for crown court: developing statistical assessment techniques at the design stage.

The ventilation performance of a proposed naturally-ventilated court-room was predicted and assessed on a statistical basis with regard to the local…

Perera M D A E S, Walker R R, Tull R G
The large area quantitative visualisation method of air streams.

The project is aimed to develop the quantitative method of visualization of the air steams in application to the indoor problems of heauilg , ventilating…

Gottschalk G, Tanner P A, Suter P
Air leakage between apartments.

Air leakage through the building envelope is of great importance for the energy use of a building. However, from an indoor air quality standpoint, the size…

Levin P
Experimental analysis of air diffusion in a large space.

An experimental study in reduced scale model for ventilation inside a sheep-fold has been studied. The ventilating system consist of two slots in opposite…

Fissore A, Nusgens P
Market analysis of sensors for the use in demand controlled ventilating systems.

In the framework of a project of the International Energy Agency (IEA) , IEA-Annex XVIII - Demand Controlled Ventilating (DCV) Systems, which started in…

Raatschen W
Displacement ventilation by different types of diffuses.

The paper describes measuring results of the air movement from three different types of diffusers for displacement ventilation. Two of the diffusers are…

Nielsen P V, Hoff L, et al
Showing 1 to 20 of 45. Page 1 of 3