Skip to main content

International Journal of Ventilation, Volume 7, 2008-2009

Volume content
A Novel Method to Measure the Air Entrainment Ratio of an Active Chilled Beam

This paper presents a new simplified method to measure the air entrainment ratio of an active chilled beam or induction unit. The method uses a single…

Mika Ruponen and John A. Tinker
A Numerical and Experimental Evaluation of a Natural Wind Driven Suction Cylinder for Building Ventilation

The suction cylinder described in this paper is a device to increase the ventilation flow rate, especially in naturally ventilated buildings. Outdoor wind…

J. Guha and S. Holmberg
A Paradigm Shift to Ensure Proper Ventilation and Better IAQ - The Energy Savings and Cost Benefits of a Dedicated Outdoor Air Approach

An energy and cost analysis has been performed which compared a dedicated outdoor air system (DOAS) with chilled radiant cooling panel (CRCP), designed for…

R Anand, C Senthil Kumar, P Hari Ramakrishnan and G Prabhakaran
A PQ-Formulation for Ventilation Duct System Flow Analyses

A formulation to analyze ventilation duct system airflows employing, as the basic unknowns, the flow rates in the channel sections and the static pressures…

Eero-Matti Salonen and Rauno Holopainen
Active Chilled Beam Wall Jet Prediction by the Free Convection Model

In this study, the measured and predicted air distribution of an active chilled beam in a typical office room is described. A free convection model was…

Guangyu Cao, Jarek Kurnitski, Panu Mustakallio and Olli Seppänen
An Experimental Analysis of the Two-Zone Airflow Pattern Formed in a Room with Displacement Ventilation

This paper presents the results of tests on the two-zone airflow pattern that forms in a room with displacement ventilation under conditions of various heat…

Z. Trzeciakiewicz
Analysis of the Ventilation System of an Isolation Room for a Hospital

The present work contains the details of an investigation of air diffusion and comfort issues of an isolation room of a hospital. Two types of cases have…

Rajeev Kumar, Ravi Kumar and Akhilesh Gupta
Comparison between Numerical and Observed Air and Contaminant Distribution for Mechanical Mixing and Displacement Ventilation Coupled with a Local Exhaust - Lessons Learnt

CFD modelling can be used in the design of ventilation systems. However, simplifications in room airflow models may lead to errors and discrepancies between…

Barbara Lipska
Development of Effective Ventilation System for Electric Multiple Unit (EMU) Train for Mumbai Suburban Railway

In the Island city of Mumbai, the Suburban Railway System operates 2500 EMU trains each of 9 or 12 cars and 6.3 millions passengers commute per day. It is…

P.C. Sehgal, A.K. Malhotra and Alok Kapoor
Effect of Free Cooling on the Operation of a Desiccant Evaporative Cooling System

Desiccant cooling is a potentially environmentally friendly technology which can be used to cool buildings without the use of traditional refrigerants. We…

Chadi Maalouf, Etienne Wurtz and Laurent Mora
Effects of Intermittent Air Velocity on Thermal and Draught Perception during Transient Temperature Conditions

Previous research has shown that air movement has a significant influence on humans’ thermal comfort. For persons feeling cool, air movement tends to be…

Wigö H.
Estimation of the Effectiveness of Cross Ventilation as a Passive Cooling Method for Houses

The effectiveness of various methods for saving energy and improving the indoor environment in buildings depends upon the building conditions under which…

Takao Sawachi, Shigeki Nishizawa, Hiromi Habara and Hisashi Miura
Evaluation of Local Thermal Discomfort in a Classroom Equipped with Cross Flow Ventilation

This paper presents an evaluation of the local thermal discomfort level in a classroom equipped with cross ventilation, for a typical moderate summer day in…

Eusébio Z. E. Conceição, Mª. Manuela J. R. Lúcio, Vitor D. S. R. Vicente and Vítor C. T. Rosão
Functional Availability of HVAC Systems

The capability of HVAC systems is of interest when contracting specific function criteria such as room temperature. The probability of maintaining the…

Myrefelt S.
Horizontal Air-to-Earth Heat Exchangers in Northern Italy - Testing, Design, and Monitoring

Earth heat exchange (EHX) through buried horizontal air ducts (EHXair-hor) can be an effective passive/hybrid system to reduce heating and cooling loads in…

Grosso M and Raimondo L.
Integrating Active Thermal Mass Strategies with HVAC Systems: Dynamic Thermal Modelling

Active thermal mass strategies can be used to enhance the performance of thermal mass through integration with the heating, ventilation and air conditioning…

D.J. Warwick, A.J. Cripps and M. Kolokotroni
Low Energy Cooling of Buildings in Central Europe - Case Studies

This paper addresses the applicability of passive and low energy cooling technologies in the Czech Republic. The main research methods are climate analysis…

Lain M, Zmrhal V and Hensen JLM.
Measurement of Natural Ventilation Rate in a Japanese Residential Building

It is difficult to design a naturally ventilated indoor environment because there is insufficient knowledge to evaluate the effect of the natural…

Nishizawa S, Sawachi T, Habara H and Seto H.
Multizone Age-of-Air Analysis

Age-of-air is a technique for evaluating ventilation that has been actively used for over 20 years. Age-of-air quantifies the time it takes for an elemental…

Max H. Sherman
Numerical and Experimental Study of an Airing Device for Controlled Natural Ventilation of a Building

The rationale of an advanced natural ventilation system should be to control airflows and air temperature during winter, and to avoid unnecessary energy…

Marco Simonetti and Gian Vincenzo Fracastoro
Showing 1 to 20 of 32. Page 1 of 2