Skip to main content

Bibliographic database Airbase

AIRBASE is the Bibliographic Database of the AIVC.

It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc.

Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

What is the status quo of airtight building in Germany? Are we well on our way or still far from the target? What about measuring practice in Germany? Should we concentrate on the documentation of measurement results or is it more important to exert a positive influence on the building process overall? Which requirements and targets...

Oliver Solcher

I have already talked about the issue of airtightness designs in Swiss standards at the Buildair Conference in 2015. What are the challenges we are facing two years later, regarding airtightness in Switzerland? And which of the issues in this context could be of interest for other countries...

 

Michael Wehrli

When building is set on very low negative pressure, use the Radon sniff-equipment called RAD7 to count radon at places where thermal imaging camera tell there is draft that can be assumed tob e leaks from the ground. If the found leakages are from the ground it often show higher level of Thoron, Radon and Polonium values, than the...

Hans Ananiassen

It has been ten years since the publication of a draft proposal, and now, many hundred measurements without a binding standard for such a sensitive area later, the day has finally come. We have a standard dealing exclusively with the airtightness of clean rooms. The presentation shows the way to the new VDI 2083/19 and...

Daniel Jung

Since 2008 in France, all measurement of building envelope airtightness performed according to the EP-regulations have to be performed by a certified operator. This certification includes a yearly follow-up we use to build up a highly detailed database which includes data of about 90,000 airtightness measurements...

Adeline Bailly Mélois, Gaëlle Guyot, Valérie Leprince

To describe the effectiveness of the thermal anemometer device in assisting airtightness testers to evaluate leakage zones, and specific leakages. There are two main aspects: While the building is pressurised to 50Pa use is made of internal doorways to close off each room to make a 'zone', and an airspeed reading is taken...

Gavin Ó Sé

Over the past years, the industry has launched a great number of products facilitating the airtight installation of sanitary fixtures in the airtight building envelope. However, the pre-wall mounting racks of cisterns remain a “key point” for assessing the airtightness of pre-walls. As part of the rehabilitation of an indoor swimming pool, “airtight”...

Thomas Runzheimer

Airtightness/air permeability are inseparable from leakages and their detection, categorization, or evaluation. The diverse contexts due to the main construction methods, structures, materials used, individual conditions on site for each building, and the perspectives of the different disciplines regarding airtightness, make it hard to take quick...

Klaus Vogel
Displaying 1169 - 1176 of 24599