Skip to main content

The 10th AIVC Conference - Progress and trends in air infiltration and ventilation research, was held in Espoo, Finland, 25-28 September 1989.

Contains 52 papers.

Volume content
Testing of heating and ventilation equipment with the duct test rig.

Canadian research into residential ventilation and combustion venting revealed that the installed performance of exhaust equipment, ducting passages, and…

Fugler D
Demand controlled air ductwork.

A demand controlled air ductwork should be so dimensioned that the flow controllers have good flow and acoustical operation conditions. From the air flows…

Laine J
A comparison of different methods of calculating interzonal airflows by multiple tracer gas decay tests.

Measurement methods based upon multiple tracer gas techniques have become an established branch of the study of air infiltration and interzonal air…

Irwin C, Edwards R E
Mathematical modelling of infiltration and ventilation.

It is particularly important to be aware of the air flow pattern in a building when determining indoor air quality problems or calculating space…

Feustel H E
The COMIS Infiltration Model.

The COMIS workshop (Conjunction of Multizone Infiltration Specialists), using a multi-national team, is planning to develop a reliable, smooth running…

Feustel H E, Grosso M, Phaff J C, Allard F, Herrlin M, Utsumi Y, Dorer V B, Liu Mingsheng, Yoshino H
The h,x-diagram as representation of measurements of ranges of comfort in a long duration test.

A new visual method is yielded by a particular application of Mollier's h,x-diagram. Point fields (temperature and humidity) lead to a significant…

Trumper H, Jansen W
Air changes and scatter in mechanical ventilation rates in Swedish residences.

In Sweden, the energy crisis in the early seventies resulted in attempts to lower the air change rate in buildings to reduce energy consumption. For many…

Lyberg M D, Boman C A
A modern concept for office buildings: energy saving and good indoor climate are no longer contradictory.

An up-to-date design concept for office buildings results in a very low energy consumption and provides a better indoor climate at the same time. This new…

Braun W
Wind and pressure requirements for the validation of a multizone air air infiltration program.

In order to be validated, the computer programs simulating the air flows in multizone buildings need several measured data sets to be compared with. Such a…

Furbringer J M, Compagnon R, Roulet C A, Gadilhe A
Air infiltration in Canadian homes - a decade of change.

This paper explores the results of air infiltration and ventilation research carried out in Canada over the last decade and specifically examines its…

Riley M, Lawton M
Ventilation by displacement: calculation of the flow in a three-dimensional room.

Displacement flow systems are becoming popular, especially in Scandinavia, for comfort ventilation. In these systems air is supplied near the floor at low…

Davidson L, Olsson E
Public policy considerations and the development of a code for the control of radon in residences.

Building codes that address radon control in residential buildings are a relatively new development in the larger trend toward increased efforts to…

Nuess M, Price S
Air change in flats with natural ventilation: measurements and calculations.

The air change rate in existing, older blocks of flats having natural ventilation has been measured by the tracer gas method. Measurements were made in the…

Olsson-Jonsson A
Airflow simulation techniques - programs and trends.

The paper describes the development in airflow simulations in rooms. The research is, as other areas of flow research, influenced by the decreasing cost of…

Nielsen P J
Ventilation, air flows in buildings and indoor air quality - R D & D and developments in Germany.

Ventilation, infiltration, indoor air flows and air exchanges determine two aspects of fast growing interest: the energy balance of buildings and the indoor…

Trepte L
Displacement ventilation for office buildings.

A test room with a Displacement Ventilation System has been built. Air velocity and temperature profiles were measured at different places in the room under…

Kegel B, Schulz U W
Outdoor air inlet without draught problems.

This paper presents a new technique for supply of outdoor air directly through external walls into a dwelling room without any draught problems. A new type…

Werner G
Coupled air flow and heat conduction model for mechanically ventilated foundations.

Rising moisture from the ground has caused quite a lot of damage on foundations of Swedish buildings. It is in some constructions possible to prevent this…

Hagentoft C E, Harderup L E
An overview of infiltration and ventilation developments in France.

France is one of the European countries where ventilation has the most advanced regulation. Vertical ducts have been used for a very long time, making…

Jardinier M
Envelope leakiness of large, naturally ventilated buildings.

Whole-building pressurisation tests can quantify the air-leakiness of a building's external envelope. The resulting information can be used in assessing the…

Perera M D A E S, Tull R G
Showing 21 to 40 of 53. Page 2 of 3