The 11th AIVC Conference - Ventilation system performance, was held in Belgirate, Italy, 18-21 September 1990.

Contains 46 papers. 

Volume content
Measurements of sub floor ventilation rates - comparison with BREVENT predictions.

The performance of ventilation provision in subfloor cavities is relevant to the fields of energy efficiency, condensation risk, and air quality. Thorough…

Edwards R, Hartless R, Gaze A
Demand controlled ventilation systems for dwelling-houses of the future.

The functional and technical requirements which have been set for ventilation systems in dwelling houses of the future will result in ventilation systems…

Kohonen R
Interaction between air infiltration and combustion appliances - validation of a numerical model.

This paper presents some of the early theoretical work conducted within the framework of a research program aimed at analysing the interaction between gas-…

Fracastoro G V, Masoero M, Mazza E
Prediction of the performance of various strategies of subfloor ventilation as remedial action for radon problems.

In order to reduce the convective flow which is the principal responsible for the high indoor 222Rn concentrations, several mitigation technics have been…

Cohilis P, Wouters P, L'Heureux D
Indoor air flow and pollutant removal in a room with task ventilation.

In an experimental facility, we studied the performance of a task ventilation system designed for use in office buildings. With this system, occupants can…

Fisk W J, Faulkner D, Bauman F S, Arens E A
Air curtains for infiltration control - a computational fluid dynamics analysis.

An investigation has been carried out using computational fluid dynamics methods to study the performance of an air curtain at the door of a heated building…

Lam J K W, Ruddick K G, Whittle G E
Tests of localized ventilation systems in a new controlled environment chamber.

This paper describes tests of thermal and ventilation performance of two relatively new occupant-controlled localized thermal distribution (also called task…

Arens E A, Bauman F S, Johnston L P, Zhang H
Calculation of the air flow pattern in a proposed new European test chamber for radiators.

A new European norm for measuring the heat transfer rate of radiators is under discussion [ CEN TC 130 ]. This testing can be done either in a closed…

Huber A, Moser A, Chen Q
The man-machine-interface for the air exchange measurement system multi-cat.

The use of computers for data acquisition and analysis in air exchange measurements with tracer gases has become state of the art for the researcher.…

Rabenstein R, Heidt F D
The ventilation chamber of the University of Basilicata.

A new facility for the study of ventilation in buildings has been recently developed at the University of Basilicata (Potenza, Italy). This facility…

Fracastoro G V, Nino E, Coretti G
Experimental evaluation of a hygroregulating natural ventilation system.

In the framework of a CEC-DGXVII demonstration project a hygroregulating natural ventilation system is being evaluated in 52 occupied apartments. Therefore…

Wouters P, Vandaele L
Ventilation systems and removal of particles.

As part of the IEA Research Program Annex 18 "Demand Controlled Ventilation Systems" various ventilation systems were examined in a test room. During…

Schwab R, Mayer E
An automated apparatus for air infiltration measurements with tracer gases.

This paper describes the activity on Air Infiltration and Ventilation of the research group of "Dipartimento di Energetica" in Politecnico of Turin. The…

Borchiellini R, Cali M
Building performance and ventilation system.

With a dynamical model, the thermal behavior of a single office room is simulated. The model includes among other things the behavior of occupants, the heat…

Braun W
Comparison of tracer-gas methods for measuring air flows in two-zone buildings.

This paper discusses three methods for measuring interzonal air movements in two zone buildings: 1. initial injection of one tracer into a single room, 2.…

Heidt F D, Rabenstein R, Schepers G
Two-directional air movements in stairwells.

The predominant route for air movements between the floors of two-storey dwellings is via the stairwell. Such air movements are of significance in the…

Edwards R, Irwin C
Ventilation and indoor air quality - a design engineer's point of view.

Keynote speech describes the difficulties of designing air conditioning system with human comfort in mind. Lists design fundamentals for satisfactory indoor…

Sandelewski A
Measurement of airflow in HVAC systems using tracer-gas techniques.

This paper describes the use of tracer-gas techniques to measure airflow in a rectangular duct and a HVAC system. Experimental procedures are discussed for…

Riffat S B, Holmes M
Air flow through building slits and components.

Pressure models require a good knowledge of the pressure distribution around the building and a precise description of air paths. The hydrodynamic behavior…

Fleury B A
Intelligent buildings: innovative techniques for the environment.

With respect to architecture and building materials, this reorientation process has led to advanced technological developments designed to achieve a…

Seyer R, Trepte L