The 17th AIVC Conference - Optimum Ventilation and Air Flow Control in Buildings, was held in Gothenburg, Sweden, 17-20 September 1996.
Contains 62 papers.
Volume content
The book of proceedings from the 17th AIVC Conference "Optimum Ventilation and Air Flow Control in Buildings", Gothenburg, Sweden, 17-20 September 1996…
This paper reports on the ventilation measurements in a cinema using the tracer-gas technique. Both the local and room air exchange efficiencies were…
The use of computers for simulating building thermal behavior started early at the Royal Institute of Technology in Stockholm, Sweden. The first example of…
This paper is describing the first results of the Annex 27 work aiming at developing simplified tools for evaluating domestic ventilation systems by using…
The problem of sensation of draught in ventilated spaces is connected to inappropriate velocities in the occupied zone. In Scandinavia, velocities higher…
Natural ventilation studies were carried out within the frame of PASCOOL EC Research Project. Research on this topic included experimental and modelling…
Ad Hoc Group 4 of Working Group 2 of CEN TC156 (Ventilation) was set up to put forward standardised techniques for estimating ventilation rates in dwellings…
Electric utilities in the Pacific Northwest have spent over $100 million to support energy efficiency improvements in the HUD-code manufactured housing…
Full scale measurements of air flow velocities, temperature, intensity of turbulence and air exchange rate are carried out on two rooms with different types…
Wind towers (scoops situated on the roofs of buildings to catch the wind) have been in use for centuries in the Middle east and Pakistan, to provide…
A Probabilistic model of air change rate in a single family house based on full-scale measurements has been developed. The probability of air change rate…
Since 1985 more than 170 very low energy houses, all of the same type and structure, were built in the Flemish Region, Belgium. Because conduction losses…
The homogeneous emission passive tracer gas technique is described. This technique relies on an even distribution of constant tracer gas emission rate…
System safety of the performance of mechanical ventilation systems can of course be analysed by means of general methods for system safety analysis. Such…
Ventilation by displacement is a type of ventilation where the air flow is thermally driven. By this arrangement one obtains two zones in the room - a lower…
The use of local exhaust is considered to be the most effective way to control pollutant dispersion from intense sources, such as in kitchens, in toilets,…
Although the power law has been broadly accepted in measurement and air infiltration standards, and in many air infiltration calculation methods, the…
The project described in this paper has performed simulations using a multi-zone air flow model (4(COMIS)) of three different passive stack ventilation…
The work presented in this paper is aimed at the definition of tracer gas experimental procedures for measuring the air change rate, the age of air and the…
Train tunnels and subways are an interesting field of ventilation. Trains move air through tunnels at rates of 600 m³/s (over 2 x 10^6 m³ per hour) which is…