Skip to main content

The 25th AIVC Conference, Ventilation and retrofitting, was held in Prague, Czech Republic, 15- 17 September 2004.

Contains 51 papers

Volume content
Checking the compliance of residential ventilation systems in France

This paper addresses the issue of the compliance of residential ventilation systems with building regulations. Because the French building code includes…

Carrié F.R., Garin D.
Performance and applications of Gossamer windTM solar powered ceiling fans

Research has shown that highly efficient solar powered ceiling fans improve thermal comfort and potentially provide health benefits when air conditioning or…

Lubliner M., Douglass J., Parker D., Chaser D.
Estimation of the effective fresh air supply rate on two storey dwellings employing stack effect ventilation

This study deals with the ventilation performance of two storey dwellings employing stack effect ventilation to satisfy the overall ventilation requirement…

Tajima M., Sawachi T., Okabe M.
Blower door tests (EN 13829) for quality assurance : getting air-tight buildings in retroffiting, too

For retrofitting as well as for new buildings a good airtightness is an important issue. In Germany, Austria and Switzerland about 1000 persons conduct…

Dorschky S.
Setting up a database of indoor climate measurements in recently built Belgian dwellings

One of the major sources of problems in dwellings -if not the main source- is moisture, especially due to surface and interstitial condensation on walls and…

Heijmans N., Wouters P., Dobbels F., Houvenaghel G., Vandermarcke B.
Energy consumption, thermal comfort and indoor air quality in schools

School buildings in Flanders are quite old. They cause concern not only about energy efficiency but also about thermal comfort, indoor air quality, speech…

Hens H., Muyldermans S., Saerens
Ventilation - The challenges and achievements

Major ventilation developments covering systems, measurements and design methods have taken place over the last 25 years. Our understanding about the impact…

Liddament M.W.
Monitoring on HR-vent hybrid ventilation project - first results

More than 700 million of measured data, 730 days, 55 dwellings: the HR-VENT hybrid ventilationdemonstration project applied in NANGIS (France) on a set of…

Siret F., Savin J.L., Jardinier M., Berthin S.
Cooling in house in Southern Europe without chillers

COOLHOUSE demonstrates the use of passive cooling techniques in southern regions of Europe which are aimed at giving comfortable summer conditions in…

Burton S., Fjearem A.
Indoor air quality in classrooms of renovated school building in Lithuania

The purpose of this study was to assess indoor air quality as well as actual ventilation in renovated school classrooms. A typical naturally ventilated…

Jurelionis A.
Numerical and experimental device for local control of ventilation

Local control of ventilation in large buildings is considered to be a main issue in energy savings regarding the huge energy losses that are usually induced…

Cordier N., Michel P.
Natural ventilation of residential buildings in protuguese winter climatic conditions

In this paper, the current situation of Portuguese residential buildings in terms of ventilation systems ispresented. The indoor air renewal is, normally,…

Ferreira M., Corvacho H., Alexandre J.L.
EU Reshyvent - Interim results

Within the EU RESHYVENT project four demand controlled ventilation systems have been developed, each one for a specific application field. The scientific…

Op't Veld P.
Experimental and numerical studies on indoor air quality in a real environment

This paper deals with the relevance of Computational Fluids Dynamics (CFD) results confronted tomeasurements carried out under uncontrolled thermal…

Akoua J.J.A.A., Allard F., Beghein C., Collignan B., Millet J.R.
Hybrid ventilation and user behaviour in summer

Hybrid ventilation is one promising approach to reduce energy consumption in office buildings. On the one hand, a minimum air change rate is supplied to the…

Pfafefferott J., Herkel S., Knapp U.
Demand controlled hybrid ventilation for cold climates

The aim of the project is to study, develop, build (prototype system) and evaluate an energy efficient demand controlled hybrid ventilation system for…

Blomsterberg A., SandbergvE., Lonnberg M.
Relative humidity analysis, retrofitting the Sint-Pieterschurch in Ghent

The Sint-Pieterschurch in the city of Ghent is one of the largest churches of the city. It was built in the 17th century. The city council wants to use the…

De Paepe M., Uyttenhove W., Janssens A.
Demand controlled ventilation applicable for any air tightness level and occupancy ?

The Dutch housing stock consists for about 70% of single family houses with an average N50 of about 7-9 ACH and for 30% of apartments with an average N50 of…

Jacobs P., de Gids W.F., Kornaat W.
Hybrid demand controlled ventilation system

The purpose of this system is to provide one improved ventilation system allowing significant good indoor air quality, heating (and cooling) energy savings…

Jardinier M., Berthin S.
The impact of energy efficient refurbishment on the airtightness in english dwellings

Fan-pressurisation method was used to test the air infiltration rate of 191 dwellings in England. All tested homes were either pre or post the introduction…

Hong S.H., Ridley I., Oreszczyn T.
Showing 21 to 40 of 52. Page 2 of 3