Volume content
Investigation of On-site Measurement of Air Flow Rate on Compact AirTerminal Devices

On-site air flow measurements of domesticventilation systems with using funnel type airflow measurement instrument which isgenerally used in Japan, has been…

Inomae, T.; Tajima, M.; Sawachi, T.
Conversion of an old brewery into a 21 st century culture and social centre

The decision makers in urban planning facevery often a dilemma whether to demolish orretrofit old buildings. Such a dileninia had to besolved during the…

Charvat, P.; Jicha, M.
Study onAirflow around Building Roof for Design ofNatud Ventilation by Chmney- Part1 Distribution of wind pressure coefficient on a building roof -

There are some ways to promote natural ventilation, but this research focuses on chimney which is traditional ventilation method used for industry or…

Watanabe, H.; Sagara, K.; Yamanaka, T.; Kotani, H.; Lim, E.; Komatsu, Y.; Higuchi, M.; Nishidan M.
Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods

Interzonal air movements are important tocharacterize overall ventilation perfosmance ofcomplicated multi-zone indoor spaces. Tracergas techniques are…

Han, H.; Cho, S.-H.
Determination of air permeability of buildings according to IS0 9972 orEN 13829 - Proposal for clarifications

Building airtightness is an important parameter that canbe measured according to the International Standard IS09972 "Therm~~l performance of buildings -…

Delmotte, C.; Caillou, S.; Van den Bossche, P.; Wouters, P.
Integration of hybrid ventilation systems in educational buildings

The case study of a nursery school of Bologna isa pilot example of how hybrid ventilationsystems can be embedded in architecturallysignificant buildings.…

L. Guardigli, M.T. Cascella
Low Exergy Systems for High-Performance Buildings and Communities

There is an obvious and indisputable need for anincrease in the efficiency of energy utilization inbuildings. Heating, cooling and lightingappliances in…

Schmidt, D.; Shukuya, M.
Power law model for wind profiles correction in urban environment

Wind speed correction based on the terraincharacteristics is commonly found in severalwind related applications in the builtenvironment. In some models…

A.P. Shimomura, A.B. Frota, D. Costola, J. Saraiva, G. Nader
Displacement Ventilation System with Radiation Panel for Sickroom-Influence of Radiation Panel on Contaminant Concentration Profile -

For the patient, the sickroom is a place for themedical treatment and is also the living spacewhere they spend almost all time in a day.Therefore, high…

N. Choi, K. Sagara, T. Yamanaka, H. Kotani, T. Suzuki, T. Yamashita
Air-related problems in high-rise buildings:How can we cope with the problems due to stack effect?

The construction of high-rise buildings beganseveral decades ago in North America, and nowhigh-rise buildings are common in East Asiaand the Middle East. A…

K.W. Kim, M.S. Yeo
Hybrid ventilation free-cooling simulation in Energy Plus. Application on ashopping center retrofitting, in Portugal.

Buildings take a great share on the total energyconsumption and C02 emissions in Portugal.Poorly thought buildings pollute the urbanspace, and contribute to…

N.M.R. Creado, M. de Matos
Effect of technical solutions on non-heating and non-cooling temperatures and free cooling potential in office buildings

In this paper we analyze by means ofbuilding simulation the effect of differentparameter combinations on the non-heating andnon-cooling temperatures of a…

Caciolo, M.; Filfli, S.; Stabat, P.; Marchio, D.
CFD Analysis of Airflow Characteristics inside Office Room with Hybrid Air Conditioning-System

The hybrid air-conditioning system is consistsof natural ventilation and mechanicalair-conditioning system in this paper. Theairflow characteristics inside…

Lim, E.; Sagara, K.; Yamanaka, T.; Kotani, H.;
Mechanical Supply Only Ventilation System for Single Family House

The Mechanical supply only (MSO) ventilationsystem has many advantages, such as good airdistribution, easy pre-heating of cold fresh airsupply and…

A. Fukushima, S. Murata, T. Morita, K. Niki
Passive ventilation systems with heat recovery and night cooling

In building design the requirements for energyconsumption for ventilation, heating and coolingand the requirements for increasingly betterindoor climate are…

Hviid, C.A.; Svendsen, S.
Performance of Whole-building Pressurization as Countermeasureagainst Stack Effect in High-rise Office Building

This paper deals with pressurization usingHVAC systems on each floor as acountermeasure against stack effect generated inthe winter in high-rise office…

Takemasa, Y.; Katoh, M.; Owada, J.; Aikawa T.; Suzuki, Y.
Non-stereoscopic 3D particle tracking velocimetry for full scale rooms

We are building a particle tracking systemfor the measurement of convective heat transfersand pollutants displacements in full scale rooms.To increase the…

P.H. Biwole, G. Krauss, J.J. Roux, G. Rusaouen, E. Favier
Applications of radiant floor cooling systems

The use of floor heating has been know sincemore than 3000 years from the Chinese Kang,the Korean Ondol, the Romans hypocaust to daysmodern water based…

Olesen, B.W.
Distribution of contaminants in the occupied zone of a room served by a novel enhanced displacement ventilation system

The aim of this study is to examine contaminantdistribution in the occupied zone of a room servedby a novel enhanced displacement ventilationsystem which…

Sun, W.; Melikov, A.K.; Cheong, K.W.D.
Contact Area and Heat Transfer of Subject with Heated Floor

It is often pointed out that when evaluating the energy-saving performance of equipment, it isimportant to take into consideration how theequipment under…

Akimoto, T.; Kagiya, S.; Matsumae K.; Kuwasawa Y.
Showing 141 to 160 of 165. Page 8 of 9