The 30th AIVC Conference, Trends in High Performance Buildings and the Role of Ventilation, was held in Berlin, Germany, 1-2 October 2009.

Contains 48 papers 

 

Volume content
Saving Heating and Cooling Energy by Sub-soil Conditioning of Supply Air at the German Museum of Technology

In 2003 the new extension of the German Museum of Technology (Deutsches Technikmuseum, Berlin), which comprises around 12,000 m?? of exhibition space was…

Johann Reiss, Hans Erhorn
Effect of the floor on the ventilation performance of the vortex vent

The vortex ventilation system (VV) which uses a rotating finned swirler installed coaxially with the exhaust duct is a very effective local ventilator. VV…

J.W. Lee, Y.B. Lim
Improving energy performance of buildings using the controlled buildings envelopes

The paper is devoted to the analysis of possibility for construction of low energy buildings withenvelopes controlled for minimization of energy consumption…

Anatolijs Borodinecs, Baiba Gaujena
The high influence of ventilation on the energy efficiency in buildings containing large-volume spaces - Example-building: The German parliament building "Reichstag" in Berlin

The influence of ventilation on the energy performance of a building is generally considered to be quite high. It rises clearly, when a building contains…

Anna Staudt, Hans Erhorn, Heike Erhorn-Kluttig
Thermal Bridges in the EPBD context

Thermal bridges increase the building energy demand for heating and cooling. For well insulatedenvelopes and buildings with increased energy efficiency, the…

Heike Erhorn-Kluttig, Hans Erhorn, Marco Citterio, Manuela Cocco, Dirk van Orshoven, Antoine Tilmans
Experimentation of Hybrid Ventilation in Carnegie Mellon University's Intelligent Workplace, Pittsburgh, PA

The Center for Building Performances and Diagnostics of Carnegie Mellon University is experimenting with Hybrid Ventilation in Pittsburgh, Pennsylvania, USA…

Flore A. Marion, David H. Archer
Indoor air quality in dwelling buildings after renovation

The paper provides the results of monitoring on the specifics of indoor air quality in Latvian dwellingbuildings. It will present the results of the…

Anatolijs Borodinecs, Zanna Budjko
Holistic Assessment Toolkit on Energy Efficient Retrofit Measures for Government Buildings (EnERGo)

The Annex 46, within the IEA ECBCS programme, is meant to influence the decision making processin the retrofit of public and governmental buildings that…

Florian Stößel, Hans Erhorn, Heike Erhorn-Kluttig, Alexander Zhivov
Airtightness requirements for high performance building envelopes

International building legislation is setting stronger and stronger requirements for the energy performance of buildings. An actual example is the impact of…

Heike Erhorn-Kluttig, Hans Erhorn, Hicham Lahmidi, Ren Anderson
Heating and Cooling of the Supply Air in Fan-Assisted Natural Ventilation System

In schools the temperature of the indoor air is one of the most important factors in terms of the indoorclimate. The resulting indoor air temperature is…

Birgitta Nordquist
Analysis of Residential Hybrid VentilationPerformance in U.S. Climates

This study examines the potential for using passive ventilation systems to meet ASHRAE 62.2requirements as a step in the process for optimizing hybrid…

Annamaria Buonomano, Max Sherman
Introduction of an Energy Efficient Ventilation System

Differences might arise between the design and the real load of ventilation systems during operation.Consequently, the fresh air demand usually varies over…

Gyöngyike Timár
EPBD and Ventilation Requirements: Uneven Inputs and Results in European Countries

Since the 2002/91/CE EPBD was published, all European countries should making efforts in harmonizing local standards, imposing the assessment of building…

S. Ferrari, V. Zanotto
Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

In Central and Northern Europe several thousands homes conform to the Passivhaus standard havebeen built. The applicability of this Standard has not yet…

L.Pagliano, P.Zangheri, S.Carlucci
Nocturnal natural ventilation for low and zero energy office buildings in Central Chile

Office buildings in central Chile normally show higher cooling than heating energy demand.Overheating is a frequent problem in this type of buildings in…

Waldo Bustamante Gómez, Elisabeth Gratia
Ventilation and low-income housing: a sensitive problem

It is well known that appropriate ventilation represents one of the prerequisites for achieving goodindoor comfort, and we try to ensure a continuous and…

M. Tomsic
Ventilation and particulate levels in dining halls

The dependence of the ventilation on the indoor particulate pollution is highlighted by numerousstudies. The aim of the present study is to examine the…

Margarita N. Assimakopoulos, Christos H. Halios, Mat Santamouris, Dafni Sfihtelli, Stathis Chrisafis
Air Distribution Effectiveness for Residential Mechanical Ventilation: Simulation and Comparison of Normalized Exposures

Even when providing the same nominal rate of outdoor air (OA), different ventilation systems distribute air in different ways, affecting the occupants…

T. Petithuguenin, M. H. Sherman
Emissions from Building Materials: Simulation of the Indoor Air Quality

The emission from materials is an important source of degradation of our indoor air quality. Toinvestigate this field, it is necessary to determine…

Samuel Caillou, Paul Van den Bossche, Luk Vandaele
Studying influence of airtightness on heating loads by coupling simplified simulation and multizone airflow model

In order to respond to global warming and natural resources depletion challenges, industrials from the building sector need to propose an adequate offer.…

M. Trocmé, B. Peuportier
Showing 1 to 20 of 48. Page 1 of 3