Skip to main content

The 35th AIVC Conference " Ventilation and airtightness in transforming the building stock to high performance", was held in Poznań, Poland, 24-25 September 2014. Contains 86 papers.

Volume content
Energy-optimal ventilation strategy outside of the operating time for passive house office buildings in cold climates

The GK environmental house is the first office building in Norway built according to the passive house concept. In such buildings, it is crucial to develop…

Per M Holth, Mads Mysen, Axel Cablè, Kari Thunshelle
Air heating of passive house office buildings in cold climates – how high supply temperature is acceptable?

The impact of over-tempered air on the perceived indoor climate was evaluated by questionnaires filled in by the users of the first office building with…

Axel Cablé, Mads Mysen, Hugo Lewi Hammer, Kari Thunshelle
Indoor climate in a Danish kindergarten built according to active house principles: measured thermal comfort and use of electrical light

The Kindergarten Solhuset is built according to the Active House vision with an emphasize of good daylight conditions and fresh air. The house was completed…

Peter Foldbjerg, Thorbjørn Færing Asmussen, Jens Christoffersen
Experiences with ventilative cooling in practical application based on experiences with completed active houses

The present paper addresses experiences with ventilation and thermal comfort in the Active House concept, based on the Active House Specification and…

Peter Foldbjerg, Kurt Emil Eriksen, Karsten Duer
Self-evaluated thermal comfort compared to measured temperatures during summer in three active houses where ventilative cooling is applied

The thermal comfort of the residential buildings Sunlighthouse in Austria and LichtAktiv Haus in Germany are investigated with a particular focus on the…

Peter Foldbjerg, Thorbjørn Færing Asmussen, Moritz Fedkenheuer, Peter Holzer
Comparison of two ventilation control strategies in the first Norwegian school with passive house standard

The Marienlyst School is the first educational building in Norway built according to the passive house standard. This building benefits from a super-…

Axel Cablé, Hugo Lewi Hammer, Mads Mysen
Cleanliness of air filters in the experimental passive house

An inherent element of the passive house is the system of exhaust ventilation in air supply. According to their class, air filters used in ventilation…

Michal Michalkiewicz, Malgorzata Basinska
Monitoring of an innovative room-by-room demand controlled heat recovery system on four locations

Demand controlled heat recovery ventilation systems, which combines heat recovery (HRV) and demand controlled (DCV) is growing fast among ventilation…

Colette Madeline, Stéphane Berthin, Pierre Kraus
Heating "passive house" offices in cold climate using only the ventilation system – comparison of two ventilation strategies

In this article we compare to ventilation strategies to heat a “passive house” office building using only the ventilation system. Two ventilation strategies…

Hugo Lewi Hammer, Mads Mysen, Axel Cablé, Kari Thunshelle
Summer performance of residential heat recovery ventilation with an air-to-air heat pump cooling system

Increasing airtightness and isolation of residential buildings in today’s climates cause challenging situations for the summer indoor climate. In…

Bart Cremers
Demand-controlled ventilation. 20 years of in-situ monitoring in the residential field

Is Demand-controlled ventilation a relevant answer to face the new challenges of the Building sector, which requires everyday higher energy efficiency and…

Jean-Luc Savin, Stéphane Berthin, Marc Jardinier
Impact of a poor quality of ventilation systems on the energy efficiency for energy-efficient houses

The “VIA-Qualité” project (2013-2016) focuses on low energy, single-family dwellings. It proposes the development of quality management approaches (ISO 9001…

Adeline Bailly, Franck Duboscq, Romuald Jobert
PROMEVENT: Improvement of protocols measurements used to characterize ventilation systems performance

For the coming energy-efficient buildings, the guarantee of energy performance becomes a major challenge. It is therefore crucial to implement accurate and…

Adeline Bailly, Cedric Lentillon
Perception of a cooling jet from ceiling - a laboratory study

The effect of a cooling jet from ceiling on thermal comfort, perception and subjective performance in warm office environment (29.5 °C) was studied.…

Henna Maula, Hannu Koskela, Annu Haapakangas, Valtteri Hongisto
Air renewal effectiveness of decentralized ventilation devices with heat recovery

Central ventilation systems with heat recovery have shown their limits especially within the context of building energy retrofit. The difficulties to…

Fabien Coydon, Jens Pfafferott
The effect of enthalpy recovery ventilation on the residential indoor climate

The indoor climate in residential buildings is affected by the people that live in the house and their activities. One of the goals of a ventilation system…

Bart Cremers
Use of DCV for heating and the influence on IAQ in passive house buildings

Measurements were performed in a test room at SINTEF building and infrastructure, Oslo. The test room is 16 m2 and built according to NS-EN 442-2. …

Vegard Aslaksen
Monitoring results and optimization of a façade integrated ventilation concept for building retrofit

An office building of the Fraunhofer Institute for Solar Energy systems (Fraunhofer ISE) in Freiburg was retrofitted in 2012 with an innovative concept…

Fabien Coydon, Maxime Duran, Arnulf Dinkel, Sebastian Herkel
Requirements and hand-over documentation for energy-optimal demand-controlled ventilation

Demand controlled ventilation (DCV) considerably reduce the ventilation airflow rates and energy use compared to Constant Air Volume (CAV) systems. DCV in…

Mads Mysen, Axel Cablé, Peter G. Schild, Kari Thunshelle
Demand controlled ventilation in renovated buildings with reuse of existing ductwork

Most existing non-residential buildings have Constant Air Volume (CAV) ventilation leading to over-ventilation in periods with low or no occupancy. Demand…

Mads Mysen, Kari Sørnes
Showing 61 to 80 of 87. Page 4 of 5