Skip to main content

The 38th AIVC Conference "Ventilating healthy low-energy buildings", was held in Nottingham, UK, 13-14 September 2017. Contains 113 papers and summaries.

Volume content
Impact of airtightness on the heat demand of passive houses in central European climate

Excessive air leakage through the building envelope increases the infiltration heat loss and therefore lowers the energy efficiency. Therefore, very good…

Aleš Vlk, Jiří Novák
Bulk airflow measurements in a large naturally ventilated atrium in a mild climate

In recent years, concerns about global warming and greenhouse gas emissions have motivated designers to reduce building energy consumption through the…

Marta Avantaggiato, Nuno Mateus, Annamaria Belleri, Wilmer Pasut ,Guillherme Carrilho da Graça
Design and performance of ventilative cooling: a review of principals, strategies and components from International case studies

Overheating is an unwanted consequence of modern building designs and internal gains that will be aggravated by the effects of climate change on local…

Paul D O’Sullivan, Adam O’Donovan, Guoqiang Zhang, Guilherme Carrilho da Graca
A comparison study of the blower door and novel pulse technique on measuring enclosure airtightness in a controlled environment

This paper introduces a comparison study of measuring the airtightness of a house sized test chamber using the novel pulse technique and the standard blower…

Xiaofeng Zheng, Edward Cooper, Joe Mazzon, Ian Wallis, Christopher J Wood
Efficiency of recirculation hoods

Recirculation hoods equipped with carbon and plasma filters are becoming more and more popular. The aim of this study is to determine the effectiveness of…

Piet Jacobs, Wouter Borsboom
A novel algorithm for demand-control of a single-room ventilation unit with a rotary heat exchanger

Energy renovations seek to improve the airtightness of dwellings and thus require ventilation and heat recovery to maintain or improve energy-efficiency,…

Kevin Michael Smith, Anders Lund Jansen, Svend Svendsen
Experimental evidence of effective single sided natural ventilation beyond 20ft or 2.5 floor to ceiling heights in open plan office spaces

Most natural ventilation (NV) systems used in non-residential buildings are single sided (SS). These systems are easy to integrate in the building layout,…

Guilherme Carrilho da Graça, Nuno Mateus, Rafael Rebelo
A longitudinal field study of thermal comfort and air quality in naturally ventilated office buildings in UK

Natural ventilation has the potential to provide cooling and fresh air and cut 40% of the total energy consumption of European office buildings. While in…

Marika Vellei, Lana Harding, Lun An, John J Orr, Ricardo Codinhoto, Sukumar Natarajan
The effect of refurbishment and trickle vents on airtightness: the case of a 1930s semi-detached house

As UK homes are insulated and draught proofed in an attempt to reduce wintertime heating demand they become more airtight. Any reduction in infiltration…

Ben Roberts, David Allinson, Kevin Lomas, Stephen Porritt
Energy Performance Indicators for Ventilative Cooling

The lack of indicators assessing ventilative cooling effectiveness in a way to compare it with active cooling technics, makes its acceptance more difficult…

Flourentzos Flourentzou, Jerome Bonvin
Method development for measuring volatile organic compound (VOC) emission rates from spray foam insulation (SPF) and their interrelationship with indoor air quality (IAQ), human health and ventilation strategies

The polyurethane foam industry is projected to reach a worldwide value of up to $74bn by 2022 and with airtightness of new and retrofitted properties…

Dzhordzhio Naldzhiev, Dejan Mumovic,Matija Strlič
Ventilative cooling potential based on climatic condition and building thermal characteristics

We introduce a new method for defining ventilative cooling potential (VCP) for office buildings that depends not only on the climatic conditions but also on…

Haolia Rahman, Hwataik Han
Towards Real-Time Model-Based Monitoring and Adoptive Controlling of Indoor Thermal Comfort

Thermal comfort is an important aspect of the building design and indoor climate control as modern man spends most of the day indoors. Conventional indoor…

Ali Youssef, Pieter Truyen, Peter Bröde, Dusan Fiala, Jean-Marie Aerts
The flow interaction of air distribution with thermal plumes and the effect on the air velocity fluctuation under increased heat load conditions

Flow interaction between thermal plumes and vertical air distribution and the resulting airflow structures were investigated under increasing heat load…

Sami Lestinen, Simo Kilpeläinen, Risto Kosonen, Juha Jokisalo, Hannu Koskela
Inter-model comparison of indoor overheating risk prediction for English dwellings

According to the 2016 Household Projections report, England’s housing stock could reach 28 million households by 2039 with approximately one fifth being new…

Giorgos Petrou, Anna Mavrogianni, Anastasia Mylona, Rokia Raslan, Gurdane Virk, Michael Davies
An interface of night ventilation and mass structure for passive cooling design strategy in Ghadames traditional dwellings

The effectiveness of night ventilation strategy for residential buildings in the old town of Ghadames has been investigated in this study. Methods of field…

Jamal Alabid, Ahmad Taki
Field measurement of carbonyl compound and particles in South Korea residential spaces

In Korea, a large amount of fine dust and carbonyl compounds is generated during cooking in the kitchen. The purpose of this study is to select 20 apartment…

KyungMo Kang, Yun Gyu Lee, Chul woong Shin
The Reintroduction of Natural Ventilation to a 19th Century Opera House, Utilising Calibrated Computer Simulation and User Operation

The Royal Wanganui Opera House (RWOH), in Whanganui, New Zealand, was constructed in 1899, and now seats 830 people. This building was designed with a…

Julia Thompson, Michael Donn, George Baird
Indoor air quality in mechanically ventilated residential dwellings/low-rise buildings: A review of existing information

Mechanical ventilation has become a mandatory requirement in multiple European standards addressing indoor air quality (IAQ) and ventilation in residential…

Amar Aganovic, Mathieu Hamon , Jakub Kolarik, Guangyu Cao
Pollutant exposure of the occupants of dwellings that complies with the Spanish indoor air quality regulations

The Spanish Technical Building Code establishes the criteria for indoor air quality fixing minimum and constant ventilation rates per local. Currently,…

Sonia Garcia Ortega, Pilar Linares Alemparte
Showing 21 to 40 of 113. Page 2 of 6