Skip to main content

The 8th AIVC Conference - Ventilation technology research and application, was held in Ueberlingen, West Germany, 21-24 September 1987.

Contains 40 papers

Volume content
The moisture load in dwellings as a function of the layout of the rooms shown by ground plans.

Measurements in some dwellings show differences of the absolute humidity as a function of the kind of ventilation (only natural or mechanical exhaust air or…

Trumper H, Hain K
Building codes designed for ensuring good indoor air quality.

All the findings about indoor air quality is of little use to the average citizen, if they are not applied and and translated into rules incorporated in our…

Ferahian R H
Measurements of infiltration and air movement in five large single-cell buildings.

A six channel, computer controlled, tracer gas detection system for the measurement of infiltration rates and air movement in large single-cell industrial…

Lawrance G V, Waters J R
An overview of the R-2000 home program design and installation guidelines for ventilation systems.

This paper outlines the development of guidelines for the design and installation of ventilation systems installed in energy efficient homes constructed…

Riley M
Developments in a multi-tracer gas system and measurements using portable SF6 equipment.

In this paper we describe the development of a multi-tracer gas system for measuring interzonal air movement in buildings. The system consists of simple and…

Riffat S B, Eid M, Littler J
Design, construction and performance of a dynamic wall house.

The construction and performance of a dynamic wall house are described. It is suggested that such houses function much like the traditional houses with…

Timusk J
Tracer gas used to evaluate HVAC equipment.

When controlling the performance of a ventilation system it is important to investigate how the system works together with the building it ventilates. It is…

Kvisgaard B, Collet P F
Measurement of seasonal air flow rates in an unoccupied single family house.

For more than four years air infiltration measurements have been made on two nearly identical side-by-side test houses in Gaithersburg, Maryland, USA. This…

Harrje D T, Bohac D L, Fortmann R C
Appliance of infrared-thermography in examining air leakage of buildings.

Sections include: measuring procedure air tightness of facades; evaluation of measuring air tightness in practice; infrared thermography; thermographical…

Adan O C G, Hendriks L W J L
A portable unit for measuring ventilation efficiency

A computerised portable unit for measuring the ventilation efficiency by the tracer gas technique is described. The hardware of the unit is designed from…

Breum N O, Skotte J
Draught measurements in ventilated and non-ventilated buildings.

Measurements of the air temperature and air velocity were carried out in four buildings without air-conditioning using a newly developed anemometer whose…

Mayer E
Advantages of microcomputer support for air change measurements.

Air change rates are measured by an IR-gas-analyser coupled with a microcomputer which is programmed to control measurements as well as data acquisition and…

Heidt F D, Werner H
Data needs for the purpose of air infiltration computer code validation.

A simplified model of air infiltration has been developed at Lawrence Berkeley Laboratory, in order to expand the use of air flow calculation techniques…

Scartezzini J L, Fuerbringer J M, Roulet C A, et al
Ventilation and leakage measurements in industrial buildings.

It has been estimated that 15% of the energy used for building services in the United Kingdom is consumed in industrial buildings. A large proportion of…

Lilly J P
Applications of a simplified model for predicting air flows in multizone structures.

A simplified pocket calculator model has been developed which can simulate the air flow distribution in multizone structures. The model is based on lumped…

Haugen T, Feustel E
The influence of temperature variation on stack effect in high-rise buildings.

A study has been made, both experimentally and analytically, on the characteristics of thermal performance of high-rise buildings using a simulated model…

Lee K H, Lee Y, Tanaka H
Use of statistics for predicting distribution of air infiltration.

Calculation of air infiltration in a large number of cases can give information of expected variations in yearly air change and energy consumptions. As…

Nielsen A F
Thermal coupling of leakage flows and heating load of buildings.

The actual heating load of a building differs often from the designed load. One reason for this is the uncontrolled ventilation through a building envelope…

Kohonen R, Ojanen T, Virtanen M
Ventilation rates and energy losses due to window opening behaviour.

This paper describes one of the results of the IEA-annex 8 "Inhabitants behaviour with regard to ventilation". Annex 8 has shown that the occupants can play…

Wouters P, De Gids W F, Warren P R, et al
Measurement techniques for ventilation and air leakage.

Ventilation has a considerable influence on both the indoor air quality and energy consumption of buildings. Three parameters can be identified which are of…

Charlesworth P S
Showing 21 to 40 of 41. Page 2 of 3