Skip to main content

International Building Simulation Conference 1999, Kyoto, Japan.

Contains 177 papers

Volume content
Simulation-based integration of contextual forces into building systems control

The research on provision of computational support for building performance analysis has traditionally concentrated on the building design phase. …

Ardeshir Mahdavi, Seongju Chang, Vineeta Pal
On capturing context in architecture

Simulation  of  visual  context  in  architecture,  the environment that surrounds both building and observer, is an…

A. J. Summerfield & S. Hayman
Regional difference of energy consumption for hot water supply system

This paper proposes useful techniques of regression analysis to estimate regional water temperatures for the optimum design of the hot water …

Minako Nabeshima and Kazuo Emura
New experimental validation and model improvement tools for the Clim2000 energy simulation software program

This  work  has  allowed  to  test  different  model improvement tools, by applying them on two building models.…

Nadia Rahni, Nacim Ramdani, Yves Candau, Gilles Guyon
Sky luminance distributuion model for simulation of daylit environment

It is important to apply the natural light effectively for the low energy consuming daylighting design. A reliable standard sky is absolutely required…

Norio Igawa, Hiroshi Nakamura and Kunio Matsuura
On the use of simulation in the design of embedded energy systems

A reduction in the emissions arising from urban activities demands a combination of energy efficiency measures and a move away from fossil fuel …

J.A. Clarke, J.L.M. Hensen, C.M. Johnstone and I. McDonald
Linking the comis multi-zone airflow model with the energyplus building energy simulation program

This paper describes an effort to link the COMIS 3.0 multi-zone airflow model with the EnergyPlus building energy simulation program. COMIS 3.0 is a…

Joe Huang, Fred Winkelmann, Fred Buhl, Curtis Pedersen, Daniel Fisher, Richard Liesen, Russell Taylor, Richard Strand, Drury Crawley, Linda Lawrie
Research on calculation method of thermal design load in radiant heating and coolind systems

A new calculation method is proposed for designing space radiant heating/cooling systems by improving conventional methods of steady and unsteady…

Hisaya Ishino
Y. Nakajima, M. Saito, J. Sugi, T. Matsumoto
Studies on the vector-flow cleanroom: numerical simulation and experiments

Based on K- two equation turbulence model, we used PHOENICS 1.4 and numerically simulated air distribution and contamination field under …

Guangbei Tu, Wenhao Chen, Lai Wang
Optimal control for central cooling plants

The optimal supervisory control strategy for a central chilled water facility has been determined. A quadratic linear regression relation for the total…

B.C. Ahn, J.W. Mitchell
Load prediction for aptimal thermal storage: comparison of three kinds of model application

It is necessary to predict the load of the following day and hours to establish optimal thermal storage. In this paper, three kinds of load prediction…

Nobuo Nakahara, Mingjie Zheng, Song Pan, Yoshihiko Nishitani
Residential Sim-Fast: software for rapid technical appraisals

This article presents the SIM-FAST software : it is a tool which allows to evaluate the energy consumption and the financial cost of French buildings…

Francis Déqué, Laurent Catusse and Sophie Castanet
Numerical analisys of human thermal comfort inside occupied spaces

In  the  present  work,  human  thermal  comfort  is investigated within the built environment. The analysis is…

C. O. R. Negrão, C. O. Carvalho Fo., C. Melo
Study into optimized control for air-conditioning system with floor thermal storage

Air-conditioning systems with floor thermal storage can be used for cutting peak load and utilizing nighttime electric power. For the effective use of…

Jung Jaehoon, Hokoi Shuichi and Urabe Wataru
Designer orientated performance evaluation of buildings

The objective of the work presented in this paper is to develop a building performance assessment tool that will assist the design process rather…

Veronica I. Soebarto and T. J. Williamson
Influence of turbulent wind on air change rates an application with Clim2000 software program

In the framework of a collaboration between EDF and CSTB, we carried out a specific experimental protocol in Bouin house (CSTB site, house …

G. Guyon, P. Girault, S. Delille, D. Hoareau, J. Villain
Effect of sweat accumulation in clothing on transient thermophysiological response of human body to the environment

The experiments involving clothed subjects are conducted to reproduce the situation in which people enter an air-conditioned room just after…

Satoru Takada, Shuichi Hokoi, Naoki Kawakami and Masanori Kudo
Evaluation of energy performance of an existing house in montreal using four energy analysis software

The purpose of this study was to evaluate the capabilities of four energy analysis software to predict the energy performance of an existing house…

R. Zmeureanu, J. Brau L. Bernard, Y. Vlym, F. Mordel, F. Timores
Determination method of coefficients and its problems in the simulation of urban air temperature based on one dimensional heat budget model

It is required that the urban air temperature is estimated on the average and macroscopically for studying the urban thermal environmental…

Masakazu Moriyama and Hideki Takebayashi
Showing 61 to 80 of 177. Page 4 of 9