Skip to main content

International Building Simulation Conference 2015, Hyderabad, India. 

Contains 85 papers.

Volume content
Spatial Variations in Overheating Risk of Dwellings Under A Changing Climate: A Case Study of Sheffield, UK

As the climate warms, the frequency and scale of extremely hot events are likely to increase. This study predicts overheating risk for the city of Sheffield…

Chunde Liu, David Coley
Grey-Box Modelling for Naturally Ventilated Buildings

Among passive strategies to reduce energy consumption in buildings, we focus on natural ventilation, which can bring an important decrease in temperature…

Ghjuvan Antone Faggianelli, Adrien Brun, Etienne Wurtz, Marc Muselli
Model Identification for the Control of Naturally Ventilated Buildings

In this paper, predictive models are developed to enable the application of model predictive control (MPC) to naturally ventilated buildings. The essential…

Joshua Stephen Sykes, Elizabeth Abigail Hathway, Peter Rockett
Evaluating Control Performance on Building HVAC Controllers

Most controllers in Heating, Ventilation and Airconditioning (HVAC) applications remain the Proportional-Integral (PI) type. Poorly performing control loops…

Yanfei Li, Zheng O’Neill, Fuxin Niu
Gradient-Based Optimal Control of Batteries And HVAC in District Energy Systems

Residential and commercial buildings use nearly 75% of the overall electrical energy in the U.S., and the amount of renewable energy in the grid keeps…

Marco Bonvini, Michael Wetter
Adaptive Thermal Building Models And Methods for Scalable Simulations of Multiple Buildings using Modelica

For building performance simulations of multiple buildings, varying objectives and data availability lead to different requirements for various model…

Moritz Lauster, Marcus Fuchs, Max Huber, Peter Remmen, Rita Streblow, Dirk Müller
Anuj Sharma, Prateek Srivastava, Jyotirmay Mathur, Mahabir Bhandari
The Implications of Transporting Architecture on Human Health

Where modern buildings are unable to maintain the internal environment to within comfort levels they often rely on mechanical systems to become habitable.…

Matthew Eames, Mike Wood, Peter Challenor
Multi-Objective Parametric Studies of Exterior Shading During Early Design Phases

Utilizing building performance feedback as part of the preliminary design process can suggest environmentally responsive strategies and inform subsequent…

Elliot Glassman
Support for Energy And Comfort Management in An Office Building using Smart Electrochromic Glazing: Dynamic Simulations

In this research, we look for a control strategy of the electrochromic windows, depending on the measurement of the vertical outdoor illuminance and the…

Youness Ajaji, Philippe André
Steady-State Psychrometric Analysis of HVAC Circuits

An HVAC circuit is a collection of interconnected elements that can be modelled by interconnected blocks. Similar to electrical or hydraulic circuits…

Christian Ghiaus
Lucie Merlier, Christian Obrecht, Frédéric Kuznik, Gilles Rusaouen, Julien Hans
Inverse Identification of Multiple Pollutant Sources

In case of an accidental release of indoor airborne pollutants, it is critical to know information of the pollutant sources. Current inverse modeling…

Yun Wei, Tengfei Zhang
Development of Personalized Radiant Cooling System for An Office Room

The building industry nowadays is facing two major challenges – increased concern for energy reduction and growing need for thermal comfort. These…

Vaibhav Khare, Anuj Mathur, Jyotirmay Mathur, Mahabir Bhandari
Effect of Window Filtration Ventilator on Indoor Thermal Comfort And Air Quality

Providing an adequate quantity of fresh, clean air to occupied areas of residential and public buildings is necessary for diluting indoor CO2, airborne…

Jiayu Li, Yuefei Hou, Junjie Liu
Modelling Mechanically Ventilated Double Skin Facades with Integrated Shading Device

Double skin façades (DSF), are typically composed by two transparent envelope elements separated by a ventilated airspace. Such a technology can be applied…

Alessandro Dama, Diego Angeli
Comparison Between the Wind Tunnel Experiment and CFD Analysis intended for Apartment house,Study of Standard k-e model and Durbin model

In this study, it is a purpose to grasp the effect of natural ventilation in the apartment house. This study targeted the apartment house of 14 floors.…

Kazuki Yamada, Yoshifusa Nishimura, Koji Sakai, Ryoichi Kajiya
Evaluation of Thermal Environment Around the Blind on Non-Uniform Radiant Fields A CFD Simulation of Heat Transfer Distribution Near the Blinds

The purpose of this research is to evaluate the indoor thermal environment under the solar shading environment. In this report, it experimented in the room…

Nozomi Saito, Hiroki Ono, Ryoichi Kajiya, Koji Sakai
Study on Modeling Method in Modularizing HVAC Elements for CFD Software

In this paper, we compared measurement results with the CFD analysis results using several of modeling methods for a four-way cassette type outlet. As a…

Ken Fukada, Koji Sakai, Hiroki Ono
Showing 21 to 40 of 85. Page 2 of 5