The 16th AIVC Conference - Implementing the results of ventilation research, was held in Palm Springs, USA, 18-22 September 1995.
Contains 51 papers.
Volume content
The book of proceedings from the 16th AIVC Conference "Implementing the results of ventilation research", Palm Springs, USA, 18-22 September 1995
…
The energy impact involved between bringing in outdoor air for indoor air pollution reduction and the energy required to condition this air are…
A computer program has been developed to predict the wind pressure coefficients Cp on facades and roofs of block shaped buildings. The program is based on…
With effect from January 1st, 1995 the amended Heat Transfer Barrier Act (,,Warmeschutzverordnung ) was introduced in the Federal Republic of Germany,…
Dynamic insulation has been used in non domestic buildings for 20- 30 years in order to reduce the heat loss and to bring preheated air into the buildings.…
To achieve acceptable indoor air quality (IAQ), ASHRAE Standard 62-1989 recommends the use of the alternative IAQ procedure. The IAQ procedure can treat…
The material presented in this paper highlights some aspects of""two research projects, The control of natural ventilation , and Night cooling strategies .…
In line maintenance hangars, air planes stay about 2 hours, usually at night-time. The coolingdown of the inside air during the opening time of the hangar…
Two factors - CO2 emissions fiom heating and cooling systems and restrictions on the use of CFC refrigerants - have accelerated the development and…
By means of a case study involving a severe case of coupled heat and sir flow in buildings, this paper aims to quantify the differences resulting from…
Air flow measurements and simulations were made on a 13-story apartment building to characterize the ventilation rates for the individual apartments.…
This paper describes a method which aims to generate an overall view of multizone building air flow by integrating methods for bulk air flow analysis, air…
A demand controlled ventilation system with humidity as the control parameter was tested in an experimental demonstration project in 16 apartments. In the…
A preliminary study of the potential for using central forced-air heating and cooling system modifications to control indoor air quality (IAQ) in…
Airtightness and infiltration rate measurements in office and other commercial buildings have shown that these buildings can experience significant levels…
ASHRAE has developed a draft of a measurement standard, Standard 129, entitled "Standard Method of Measuring Air Cliange Effectiveness." This standard…
Approved Document (AD Part F1) of the Building Regulations [1] for England and Wales identifies trickle ventilators as an option for providing natural…
A laboratory, designed to form the basis for research aiming at increasing the knowledge concerning the interactions between indoor pollution sources and…
Almost 60% of French residential buildings were built before the seventies, and an important part of those is to be retrofitted for complying with new needs…
Thirty-one independent fan pressurization measurement series were performed on seven apartments in three family housing buildings at Fort Riley, Kansas,…