The 16th AIVC Conference - Implementing the results of ventilation research, was held in Palm Springs, USA, 18-22 September 1995.
Contains 51 papers.
Volume content
The book of proceedings from the 16th AIVC Conference "Implementing the results of ventilation research", Palm Springs, USA, 18-22 September 1995
…
The energy impact involved between bringing in outdoor air for indoor air pollution reduction and the energy required to condition this air are…
By means of a case study involving a severe case of coupled heat and sir flow in buildings, this paper aims to quantify the differences resulting from…
Air flow measurements and simulations were made on a 13-story apartment building to characterize the ventilation rates for the individual apartments.…
This paper describes a method which aims to generate an overall view of multizone building air flow by integrating methods for bulk air flow analysis, air…
A demand controlled ventilation system with humidity as the control parameter was tested in an experimental demonstration project in 16 apartments. In the…
A preliminary study of the potential for using central forced-air heating and cooling system modifications to control indoor air quality (IAQ) in…
Airtightness and infiltration rate measurements in office and other commercial buildings have shown that these buildings can experience significant levels…
ASHRAE has developed a draft of a measurement standard, Standard 129, entitled "Standard Method of Measuring Air Cliange Effectiveness." This standard…
Approved Document (AD Part F1) of the Building Regulations [1] for England and Wales identifies trickle ventilators as an option for providing natural…
A laboratory, designed to form the basis for research aiming at increasing the knowledge concerning the interactions between indoor pollution sources and…
Almost 60% of French residential buildings were built before the seventies, and an important part of those is to be retrofitted for complying with new needs…
Thirty-one independent fan pressurization measurement series were performed on seven apartments in three family housing buildings at Fort Riley, Kansas,…
The use of IR detectors to steer the ventilation is in principle an attractive approach for optimising the ventilation according to the occupants needs. In…
So as to better understand and predict IAQ problems, the velocity field and distribution of local mean age of air were determined experimentally with three-…
The Building Research Establishment is currently investigating the impact of various radon remedies at a radon affected test house. Tests aim to assess how…
In order that sampling points may be strategically located, it is desirable to have knowledge of the spatial variation of ventilation eflectiveness…
For the planning of "silent cooling" systems built by free convective coolers, it is necessary to support characteristic data for the cooling performance…
The C-2000 program for advances commercial buildings is an awards program to assist in the development of energy efficient and sustainable building…
There is an increasing concern at the possible health effects of fine suspended particulate (aerosol) upon human health, particularly in the urban…