Skip to main content

 The 16th AIVC Conference - Implementing the results of ventilation research, was held in Palm Springs, USA, 18-22 September 1995.

Contains 51 papers.

Volume content
Reducing the permeability of residential duct systems.

In this paper, we investigate the potential of an aerosol-based technique to significantly reduce the leakiness of residential air distribution systems (ADS…

Carrie F R, Modera M P
Improvement of a mechanical ventilation system regarding the utilization of outdoor air.

Nowadays it is rather common with demand controlled ventilation in public buildings and offices. The purpose of demand controlled ventilation is to adapt…

Carlsson T, Blomsterberg A
Evaluation and demonstration of domestic ventilation: state of the art.

The IEA Annex 27, "Evaluation and Demonstration of Domestic Ventilation Systems" is aiming at developing tools by using the most developed computer models…

Mansson L-G
NRC indoor environment research facility.

This paper describes the new indoor environment research facility recently constructed at the Institute for Research in Construction, National Research…

Shaw C Y, Barakat S A, Newsham G R, Veitch J A, Bradley J
A report on the radon measurement in a single family house.

This paper presents the results of a series of measurements made in an occupied family house. Long and short-term measurements of the concentration of radon…

Wang F, Ward I C
Efficient work environment ventilation.

A breakthrough in ventilation research was made once it was realized that ventilation principles based on mixed flow patterns are not optimal and that…

Holmberg S, Andersson I-M, Niemela R
Indoor climate and user interaction on modern Swedish one family houses - results using a questionnaire.

Disadvantages and advantages with different heating and ventilation systems in modern housing have been discussed during many years in Sweden. The…

Blomsterberg A, Carlsson T
A simple calculation method for attic ventilation rates.

The ventilation of an attic is critical in estimating heating and cooling loads for buildings because the air temperature in the attic is highly sensitive…

Walker I S, Forest T W, Wilson D J
Air dehumidification by absortive and evaporative cooling.

Especially in modern buildings with small capacity of humidity storage it is necessary to reduce the humidity in the supply air. Normally a refrigeration…

Roeben J, Kourouma S Y
Feasibility of ventilation heat recovery in retrofitting multi family buildings.

The work concentrated on estimating the effects of building leakages and terrain parameters on the air infiltration. The analysis was performed mainly using…

Sateri J, Heikkinen J, Pallari M-L
Pressure simulation program.

A computer program has been developed to predict the wind pressure coefficients Cp on facades and roofs of block shaped buildings. The program is based on…

Knoll B, Phaff J C, de Gids W F
The new energy conservation code in the Federal Republic of Germany.

With effect from January 1st, 1995 the amended Heat Transfer Barrier Act (,,Warmeschutzverordnung ) was introduced in the Federal Republic of Germany,…

Mertz G
The indoor air quality and the ventilation performance of four occupied residential buildings with dynamic insulation.

Dynamic insulation has been used in non domestic buildings for 20- 30 years in order to reduce the heat loss and to bring preheated air into the buildings.…

Brunsell J T
Determining IAQ dynamic response to emissions.

To achieve acceptable indoor air quality (IAQ), ASHRAE Standard 62-1989 recommends the use of the alternative IAQ procedure. The IAQ procedure can treat…

Meckler M
Automatic control of natural ventilation and passive cooling.

The material presented in this paper highlights some aspects of""two research projects, The control of natural ventilation , and Night cooling strategies .…

Martin A
Application of air flow models to aircraft hangars with very large openings.

In line maintenance hangars, air planes stay about 2 hours, usually at night-time. The coolingdown of the inside air during the opening time of the hangar…

van der Maas J, Schaelin A
Criteria for heat recovery and dehumidification.

Two factors - CO2 emissions fiom heating and cooling systems and restrictions on the use of CFC refrigerants - have accelerated the development and…

Dehli F
Modelling coupled heat and airflow: ping pong versus onions.

By means of a case study involving a severe case of coupled heat and sir flow in buildings, this paper aims to quantify the differences resulting from…

Hensen J L M
Air flow distribution in a mechanically ventilated high rise residential building.

Air flow measurements and simulations were made on a 13-story apartment building to characterize the ventilation rates for the individual apartments.…

Diamond R C, Feustel H E
Predicting indoor airflow by combining network approach, CFD and thermal insulation.

This paper describes a method which aims to generate an overall view of multizone building air flow by integrating methods for bulk air flow analysis, air…

Clarke J A, Hensen J L M, Negrao C O R
Showing 21 to 40 of 52. Page 2 of 3