Airflow through louvers: an experimental and CFD study.

In this study a series of parametric laboratory measurements were made of the velocitiesoutside, ve, and inside, vi, a full-scale louver positioned in a…

Sharples S, Maghrabi A
Design pressure difference for self adjusting air inlets.

At present the design pressure difference for air inlets in The Netherlands is 1 Pascal. This paperinvestigates the question whether or not this value is…

Vollebregt R, Vrins E
Airtightness and underpressures measurements in French apartments.

Dwellings airtigthness is not well known in practice, in France.When dwellings are equipped with mechanical ventilation systems (which represents about 95%…

Barles P, Boulanger X
Demand controlled ventilation in schools - energetic and hygienic aspects

In this study, we investigated the indoor air quality (IAQ) in classrooms with exhaustventilation systems and in naturally ventilated classrooms. In the…

Weinlader H, Beck A, Fricke J
Experimental testing of a ventilated roof component for energy saving in cooling.

A Ventilated roof component was built and tested in the outdoor testing facilities (Test Cells) of CRES, Greece. A conventional Greek roof structure of the…

Dimoudi A, Androutsopoulos A, Lykoudis S
Improvement of thermal comfort in a naturally ventilated office.

In natural ventilation systems, fresh air is often provided through opening of windows, andthere is a wide range of possibilities with regard to selection…

Bjorn E, Jensen J, Larsen J, Nielsen P V, Heiselberg P
Ventilation performances in French dwellings: results from field observations and measurements.

This paper presents a recent field measurement study undertaken in 1999 on 73 recent Frenchdwellings. The study presented the opportunity to assess the…

Guillot K, Litvak A, Kilberger M, Boze D
Influence of building air tightness on ventilation losses.

The Building Air Tightness is an important parameter on ventilation systems performanceand energy losses.Yet, the total amount of leakage is as important on…

Bernard A-M, Lemaire M-C
Performance of demand controlled ventilation: case study, energy savings and practical rules.

In order to assess the real performances of different demand controlled ventilation (DCV)systems, two of them were installed in meeting rooms of an office…

Bernard A-M, Blazy M, Lemaire M-C
Performances of a new generation high efficiency heat recovery units for domestic ventilation.

In 1998 the Dutch ventilation industry launched a new generation of domestic ventilation systems on the market with high efficiency heat recovery applying…

Op't Veld P
On the impact of the urban environment on the potential of natural ventilation.

Knowledge and estimation of the wind speed and air flow characteristics, in a city, is of vitalimportance for passive cooling applications and especially in…

Santamouris M, Dascalaki E, Klitsikas N, Papakonstantinou K, Georgakis C
Experimental testing of a homogeneous tracer pulse technique for measurement of ventilation and air distribution in buildings.

A number of single tracer gas techniques (decay, step-up, homogeneous constant emission,inlet pulse and homogeneous pulse) suitable for measuring the local…

Stymne H, Hansson P, Boman C A
On ventilation needs - towards demand controlled ventilation in dwellings.

Ventilation needs in dwellings must be determined on the basis of both requirements to theindoor air quality and necessary control of moisture conditions.…

Bergsoe N C
A novel ventilation heat pump system.

The move towards improving building air-tightness to save energy has increased theincidence of poor indoor air quality and associated problems, such as…

Riffat S B, Gillott M C
The use of heat pumps to induce airflow on hot days in otherwise passive ventilation systems.

The paper presents results from a wider study into providing displacement ventilationin urban areas by taking air into buildings from the top without the…

Gage S A, Ayres P, Axon J
Environmental comfort models for individual occupants.

Conventional models of building occupants' environmental preferences such as thermal comfort are used to give guidelines for the average environmental…

Matthews I W, Virk G S, Azzi D, Raja I A
Effect of control strategies on ventilation system performance.

Dynamic computer simulations were used to compare residential ventilation methods to identifyan approach that would improve indoor air quality with minimum…

Shah D J
Controlled double facade for preheating ventilation.

In the recent past new concepts for the building envelope have been developed with theunderlying wish to improve the energy performance of a building as…

van Paassen A H C, Stec W
Noise control techniques for naturally ventilated buildings.

There has been a growing interest in the use of natural ventilation in buildings to supplement orreplace mechanical air supply systems. However, for…

Sharples S, de Salis M, Oldham D
Sol-Vent: Development of strategies for the efficient use of solar and passive ventilation in urban buildings.

This paper outlines work in progress to develop dissemination material to assist the appropriate application of solar and passive ventilation in urban…

Kolokotroni M, Santamouris M, Dascalaki E, Palmer J, Allard F, Alvarez S,""Blanco A
Showing 41 to 60 of 60. Page 3 of 3