Skip to main content

The 3rd AIVC Conference - Energy efficient domestic ventilation systems for achieving acceptable indoor air quality, was held in London, UK, 20-23 September 1982.

Contains 29 papers.

Volume content
3rd AIC Conference: Energy efficient domestic ventilation systems for achieving acceptable indoor air quality (Book of Proceedings)

Contains 23 papers as follows: Keynote Paper The art of ventilation; Use of natural ventilation; Variations in householders' window opening patterns;…

AIVC
The impact of ventilation and airtightness on energy consumption.

The total energy consumption for five detached houses with air change rates of around 3 per hour right after construction, was measured and compared with…

Logdberg A.
Reduction of air infiltration and the development of controlled mechanical ventilation in France.

Since 1974 the french Authorities have insisted on energy being saved in all buildings. There was very strong pressure on manufacturers to obtain better…

Baets F, Jardinier P.
Ventilation and energy consumption. Practical experience of problems related to ventilation in single family houses.

Discusses the problems of designing ventilation for small houses. Small houses are considered to be far too elementary and there is no total view of the…

Gusten J, Harryson C.
A method to assess the health and comfort changes among tenants after draught proofing of their flats.

The aim of the present study is to measure the possible health effects among tenants after certain characteristic energy conservation measures had been…

Iversen M, Lundqvist G R.
Energy conservation by regulation of the central mechanical ventilation system in high rise buildings: realistic or not?

The investigation was divided into several parts: 1, measurements of a mechanical ventilation system, 2, calculation model for this system, 3, measurements…

Phaff J C, De Gids W.
Efficiency of air-to-air heat exchangers in occupied houses.

The purpose of the project has been to determine the saving in energy obtained in the practical operation of an FTX-system -that is, a fan-controlled supply…

Svensson A.
Estimation of rate of air infiltration based on full-scale wind pressure measurements.

Natural and forced ventilation are directly and indirectly influenced by the pressure distribution around a building. Results of full-scale pressure…

Handa K, Gusten J.
Heat losses from small houses due to wind influence.

The heat losses from small houses, due to transmission and ventilation, are estimated. The estimation i s based up on the house owness daily readings of…

Ahlander G.
On flow in narrow slots applied to infiltration.

The normally used equation for calculation of infiltration flow rates into a house is a power law of which the exponent n is normally assumed to be 0.66 but…

Peterson F.
Ventilation patterns of windows and adjustable natural ventilation systems.

Measurements in a test room of 28.4 m3 located at the top of a 3-storey building have been made to determine ventilation rates of different natural…

Daler R, Haberda F, Hirsch E, et al.
Natural ventilation in the UK and some considerations for energy efficient design.

This paper discusses the potential for achieving an "energy-efficient" ventilation system by improving design procedures for natural ventilation. It…

Etheridge D W.
Ventilation heat loss in a detached one family house.

For optimum building design it is of importance to investigate the comfort and the energy conservation obtained with different types of ventilation systems…

Lindquist T.
The role of mathematical modelling in the design of energy efficient ventilation systems.

Explores the various roles that mathematical models can play in the design of energy efficient ventilation systems. Uses an example (an existing terraced…

Liddament M.W.
The efficiency of ventilation in a detached house.

Uses the SEGAS "Autovent" constant concentration apparatus to measure the fresh air entering and the local ventilation rate in each cell of amulti-celled…

Freeman J. Gale R. Sandberg M.
Field trials of ventilation efficiency in buildings equipped with mechanical ventilation systems.

Gives results from fiel trials of the performance of various mechanical ventilation systems. Carries out measurements in buildings built during the…

Boman C.A.
User experience of mechanical ventilation in houses.

Describes experiments carried out in 4 low energy electrically heated houses incorporating extra thermal insulation and heat recovery mechanical ventilation…

Dickson D.J.
Avoiding condensation and mould growth in existing housing with the minimum energy input.

Detailed studies of public sector modernisation programmes show that the principal problem resulting from lack of thermal insulation and inappropriate…

Finbow M.
Ventilation rates in relation to emission of gases and vapours from building materials.

Uses mathematical models for formaldehyde concentrations in 3 normal rooms in a single family house to estimate ventilation rates needed to maintain the…

Molhave L.
Ventilation and internal air movements for summer and winter conditions.

Distinguishes the problems of designing natural ventilation systems for summer and winter conditions and discusses in detail the objectives, methods and…

Howarth A.T. Burberry P.J. Irwin C. I'Anson S.J.
Showing 1 to 20 of 29. Page 1 of 2