The 6th AIVC Conference - Ventilation strategies and measurement techniques was held in the Southern Netherlands, 16-19 September 1985.
Contains 32 papers.
Volume content
Contains twenty seven papers from the sixth AIC Conference as follows: Ventilation, the balance between energy and well-being; The infiltration component of…
This paper reports the findings from tests undertaken in an untight, two-storey, brick-built detached test house. Different ventilation schemes were in use…
A multicell air flow computer program is used to determine the influence of 1) open windows and 2) closed internal doors on the ventilation rate of a semi-…
Although infiltration of outside air across the envelope of a building has been considered of prime interest in relation to energy conservation and indoor…
If the energy losses due to ventilation have obviously become an important problem since the energy crisis, there is still a lot to be done with respect to…
Measurement of air exchange rates, ages of air, and nominal and local ventilation efficiencies in large buildings is often complicated by the building size…
A survey is given of the sitution in The Netherlands with regard to ventilation and infiltration. Starting from a point of generally very leaky and hardly…
As part of a programme to develop measurement methods for determining the ventilation rates of large buildings, we performed two series of tests in a single…
Based on current concerns regarding indoor air quality and energy use, there is a need for in situ techniques for evaluating buildings' infiltration and…
A research is being carried out concerning the use of windows and doors in an appartrent building in Schiedam in the Netherlands, The…
Airtightness measurements were carried out in ten typical Dutch dwelling complexes. In each complex four homes were measured. The IMG calculation model was…
This paper describes a series of ventilation measurements carried out in two small factory units situated on an industrial estate in Newport, South Wales.…
The air infiltration component of house ventilation is calculated and discussed in relation to winter space heat losses and rneasures necessary to control…
The performance of whole-house mechanical ventilation systems was explored in an full-scale indoor test house (volume 176 m³ ) . A range of parameters were…
Pacific Power and Light Company and Battelle PNW Laboratories have completed a project which investigated residential ventilation rates. The results…
The R-2000 Super Energy-Efficient Home Program is a cooperative industry/government initiative sponsored by Energy, Mines and Resources Canada (EMR) and…
A passive ventilation system has been installed in four new houses: it comprises simple ducts which lead up from the kitchen and bathroom to outside near…
This paper discusses the indoor formaldehyde levels in two groups of houses. With the exception of the heating and ventilation systems, the house…
Natural ventilation rates in bedrooms at night have been measured in retrofitted apartments. The measurements indicate clearly that air quality in bedrooms…
Several infiltration models treat the complexity of air flows in multizone buildings, but most of them are written as research tools and are not generally…