Skip to main content

The 6th AIVC Conference - Ventilation strategies and measurement techniques was held in the Southern Netherlands, 16-19 September 1985.

Contains 32 papers.  

Volume content
Development of a simplified multizone infiltration model.

Several infiltration models treat the complexity of air flows in multizone buildings, but most of them are written as research tools and are not generally…

Feustel H E
Effect of unvented combustion appliances on air exchange among indoor spaces.

The effects of operating unvented appl i ances and opening windows on indoor pollutant levels and air exchange rates are being studied under the sponsorship…

Nagda N, Koontz M D, Billick I H
Multizone modeling and air leakage analysis.

Reviews the papers on air infiltration and ventilation research presented at the ASHRAE annual meeting held in Honolulu, Hawaii, in June 1985. The twelve…

Sherman M
Air exchange rates based upon individual room and single cell measurements.

For more than two years a series of detailed air infiltration measurements have been conducted over the complete yearly weather cycle on two identical side-…

Harrje D T, Bohac D L, Nagda N L
Monitoring of ventilation and humidity in crawl spaces of dwellings.

Several physical phenomena which may contribute to moisture migration from the crawl space to the living spaces in houses are outlined. Results of two…

Oldengarm J
Multiple cell air movement measurements.

The multiple tracer gas technique developed at UMIST has been applied to the measurement of roof-space ventilation rates and house to roof-space air…

Edwards R E, Irwin C
Ventilation strategies for crawl-spaces, attics.

In this paper ventilation of attics and crawl-spaces is investigated theoretically. Ventilation rates and temperatures of the spaces are calculated by means…

Kronvall J
Continuous air renewal measurements in different inhabited buildings.

A Compact Equipment for Survey of Air Renewal (CESAR) was developed at the Ecole Polytechnique Federale de Lausanne in Switzerland. Controlled by a…

Scartezzini J-L, Roulet C-A, Jolliet O
Use of a single tracer gas for measurement of ventilation rates in a large enclosure.

This paper describes a preliminary investigation of the validity of a means of calculating the ventilation rate of a large enclosure from experimental data…

Dewsbury J
Advanced energy-efficient ventilation.

It is often stated that advanced ventilation or air conditioning is expensive or energy-wasting. There are, however, several examples of highly energy-…

Railio J
Improving the accuracy of a constant concentration tracer gas system.

Air infiltration flows into different zones of a building can be measured with the constant concentration technique by injecting a metered amount of tracer…

Bohac D L, Harrje D T
Design for ventilation.

Ventilation can be advantageous as opposed to adventitious and, with careful building design, can eliminate the need for air conditioning in summer. This…

Holmes M J
Ventilation efficiency measurements in occupied mechanically ventilated buildings.

The various meanings of ventilation efficiency are briefly summarised. The residual life time of a released tracer gas is chosen as the most meaningful and…

Dickson D J
Showing 21 to 33 of 33. Page 2 of 2