Skip to main content

The 20th AIVC and Indoor Air 99 Conference, Ventilation and indoor air quality in buildings, was held in Edinburgh , Scotland, 9-13 August 1999.

Contains 141 papers

Volume content
Ventilation Requirements in a retail store

This field study was organized to determine the ventilation required to maintain acceptable air quality in a retail store using the ASHRAE Standard 62-1989…

D.T. Grimsrud, B.B. Bridges, N.G. Carlson, D.E. Hadlich
A review of ventilation and the quality of ventilation air.

Ventilation is pivotal both in terms of indoor air quality and environmental issues such as greenhouse gas emissions. It also has a major impact on energy…

Liddament M W
Design methods for ventilation systems in residential and commercial buildings.

The development of guidelines for smart innovative mechanical ventilation systems is a task included in an ongoing research project partly supported by the…

Blomsterberg A, Delmotte C, Barles P, Pennycook K, de Gids W, Hardegger P, Maldonado E
Pressure relationships in hospital critical-care facilities.

This field study was organised to track differential pressure relationships in critical care units of a metropolitan hospital. Maintaining design pressure…

Streifel A J, Bridges B B, Grimsrud D T, Krafthefer B C
Atmospheric turbulence influence on natural ventilation air change rates.

In order to estimate air change rates (ACH) on Natural Ventilation (NV) processes a number of factors should be known as general and openings dimensions,…

Saraiva J G, Marques da Silva F
High efficiency desiccant systems for air conditioning applications.

Suitable combinations of desiccant and evaporative cooling systems permit air processes alternative to the traditional ones for air conditioning…

Schibuola L
Natural ventilation activated by induction.

Energy-saving improvements in the thermal properties of buildings often have an adverse effect on indoor air quality, leading to risks of structural…

Baumann M-L, Amphoux A
Performance of an advanced air conditioning system during extreme weather conditions in a generator plant.

This technical note considers the performance evaluation of an advanced air-conditioningsystem in a plant manufacturing electrical generators. The extensive…

Raisanen J, Paakkari A, Niemela R
Design of ventilation routes and indoor air quality in houses using a passive ventilation system.

The feasibility of designing ventilation routes in the house with passive ventilation system is investigated using the numerical experiments and the…

Hayashi M, Enai M, Hirokawa Y, Yamashita M
Vent-convector - an experimental study.

In mechanical exhaust ventilated buildings in cold climates, the supply air through vents in the perimeter may cause draught and reduce the zone of…

Mundt E, Gustavsson M, Leksell P
Estimation of air exchange rates in Kuwaiti residential buildings.

Air exchange rates of ten residential buildings were measured according to ASTM-E741-83 using SF6 as a decaying tracer. Air exchange rates were also…

Alper E, Elkilani A S, Bouhamra W S
Development of a low energy fan convector.

A patented, low energy, fresh air fan convector has been developed by a HVAC equipmentmanufacturer in conjunction with a leading controls supplier and a…

Price M J, Clancy E M
Natural devices in the urban spaces to improve indoor air climate and air quality of existing buildings.

The role of outdoor spaces’ design as well as the mutual correspondence among urban microclimate, indoor air climate and air quality, have been specifically…

Ferrante A, Mihalakakou G, Santamouris M
Method of air parameters control while processing in air-handling units of HVAC systems.

Based on theoretical and experimental tests it was determined that the thermodynamic balancecondition in the working space of air-handling units (AHUs) of…

Gvozdkov A N, Bogoslovsky V N
Measurement of air flow rates and ventilation efficiency in air handling units.

Air handling units do not always function as planned: airflow rates are often larger than required, the recirculation rate is not at its set-point value and…

Roulet C-A, Foradini F, Deschamps L
Ventilation air intake - first line of defence against an unfavourable outdoor climate.

The ventilation air intake (louver) is the first line of defence against an unfavourable outdoor climate. Unfortunately, the importance of this component is…

Kristiansen O, Hanssen S O, Stang J, Lysne H N
A humidity control system with an adsorption material and indoor air quality improvement.

The present study introduces a humidity control apparatus which can hygienically and automaticlymaintain the appropriate humidity level of indoor air…

Moriya Y, Yoneno N, Oyama M, Tanabe S
Heat and moisture exchange in counterflow rotary air dehumidifier.

This present work has theoretically investigated coupled heat and mass exchangemechanisms in counterflow rotary dehumidifier with the mixed desiccant of…

Anisimov S
Error estimation of blower door measurements by computer simulation.

Computer simulation of building airtightness measurements shows the effect of changes inpressure distribution across the building envelope due to wind force…

Geissler A
Microbial investigations and allergen measurements in ground-coupled earth-to-air heat exchangers.

Different ground-coupled earth-to -air heat exchangers have been constructed in many residential and occupational buildings in Switzerland to precool or…

Flueckiger B, Monn C