Skip to main content

The 20th AIVC and Indoor Air 99 Conference, Ventilation and indoor air quality in buildings, was held in Edinburgh , Scotland, 9-13 August 1999.

Contains 141 papers

Volume content
Performance of automotive cabin air filters.

The cabin air filter performance is of prime importance for the air quality in vehicles. New clean filters were tested but also filters loaded with actual…

Johansson J, Jansson A, Olander L
Individual air distribution control panel on partition panel at personal task area.

A general trend in intelligent buildings is the decentralization of environmental controlsystems. Decentralized environmental control systems have many…

Jeong K-B, Kim J-J
The influence of an architectural design alternative (transoms) on indoor air environment in conventional kitchens in Taiwan.

This study investigates indoor air environment via the flow fields, temperature fields and air contaminants (carbon monoxide) distributions in conventional…

Chiang C-M, Lai C-M, Chou P-C, Li Y-Y
A simulated test for cleaning efficiency of two kinds of indoor air cleaners.

Indoor air quality is decreasing year by year. It is very necessary to find a kind of efficient cleaner to improve the indoor air quality. Two kinds of…

Liu J Z, Pan X C
The effects of improved residential filtration on particulate exposure.

Forced air furnaces are a common Canadian heating system. Traditionally, filters placed in thecirculating air ductwork were designed to protect the furnace…

Bowser D, Fugler D, Salares V
Assessing the performance of room air cleaners using a room environmental chamber.

Models are presented for describing the performance of room air cleaners in removing pollutants from indoor air, particularly the levels of removal that can…

Brown S K
Performance of passive stack ventilation with heat recovery system.

In order to explain the effect of heat recovery on a passive ventilation system using stack effect, and to show the factors and conditions that the heat-…

Sasaki T, Hayashi M, Enai M, Hirokawa Y
Do plants in an office have any effect on indoor air microorganisms?

The role of indoor plants as a source of microorganisms was studied in six office rooms.Concentrations of microorganisms (both fungi and actinomycetes) were…

Rautiala S, Haatainen S, Kallunki H, Kujanpaa L, Laitenen S, Miihkinen A, Reiman M, Seuri M
The effect of loading dust type on the filtration efficiency of electrostatically-charged filters.

Ventilation filters composed of electrostatically-charged fibers, also referred to as electret filters,are know to have the potential to decrease in…

Hanley J T, Ensor D S, Foarde K K, Sparks L E
Evaluation of electrostatic precipitator performance for submicron particle size range.

The fractional collection efficiency (FCE) tests of a commercially available two-stageelectrostatic precipitator (ESP) have been performed for six flow…

Agranovski V, Morawska L, Ristovski Z, Jamriska M
Monitoring indoor relative humidity fluctuations associated with intermittent operation of air conditioners.

In residential buildings, air-conditioners are usually operated in intermittent mode. Thisintermittent mode may complicate many aspects of indoor…

Niu J L, Burnett J
Adsorption purification of indoor air, mainly from formaldehyde.

Formaldehyde (FA) adsorption, including that in the presence of water vapours, has been evaluated on adsorbents of various nature and porous structure. The…

Chirkova J, Andersons B, Druz N, Andersone I
Long-term testing of gas adsorption filters for ventilation systems.

A test rig for long-term tests of activated carbon filters was developed consisting of eight parallel test-filter sections. The test-rig was installed on…

Ekberg L E, Strindehag O
The optimisation of UVGI air disinfection in a UK hospital building.

A number of studies have shown that approximately 1 in 10 hospital in-patients will acquire a nosocomial infection (NI) '*).These infections are associated…

Beggs C B, Sleigh P A, Donnelly J K, Kerr K G, Mara D D
The impact of wind turbulence on the precision of a numerical modelling study.

The aim of this study is to illustrate the importance of the effects of wind turbulence on airchange in buildings. Using two simple configurations, tested…

Girault P, Spennato B
Particle concentrations in an air conditioned office building with normal and high efficiency filtration.

Indoor and outdoor particle concentrations and ventilation rates were measured versus time ina large office building without tobacco smoking. Periodically,…

Fisk W J, Faulkner D, Sullivan D P, Mendell M J
Dynamic water vapour sorption: measurement and modelling.

The objectives of thisinvestigation were to examine the dynamic water vapour sorption offurnishing materials and to compare the experimental results…

Plathner P, Littler J, Stephen R
Influence of natural convection on the thermal properties of insulating porous medium with air cavity.

The influence of natural convection on the thermal properties of insulating porous medium with air cavity is studied. Here, the combined effect of air…

Shankar V, Hagentoft C E
Combined control of natural and forced ventilation using intelligent control algorithms.

Results are presented from a study of the performance of fuzzy, rule-based algorithms for thecontrol of indoor air quality through combined control of…

Sutherland G, Eftaxias G, Santamouris M, Asimakopoulos D
Neural model for air exchange in habitable rooms.

Recent years have brought the popularity of methods in which neutral networks are applied. They seem of particular importance while dealing with diagnosing…

Piotrowski J Z
Showing 61 to 80 of 141. Page 4 of 8