The impact of wind turbulence on the precision of a numerical modelling study.

The aim of this study is to illustrate the importance of the effects of wind turbulence on airchange in buildings. Using two simple configurations, tested…

Girault P, Spennato B
Particle concentrations in an air conditioned office building with normal and high efficiency filtration.

Indoor and outdoor particle concentrations and ventilation rates were measured versus time ina large office building without tobacco smoking. Periodically,…

Fisk W J, Faulkner D, Sullivan D P, Mendell M J
Servicing the Millennium Dome.

With a diameter of 320m, and a height of 50m the Millennium Dome is one of the World's largest enclosed spaces, probably the largest among those intended…

Cripps A J, McLaughlin T, Carmichael K
In situ measurement of air cleaner ventilation effectiveness.

A test room was used to evaluate the impact of airflow parameters on the effectiveness of an air cleaning system. The room’s dimensions were nominally 11.2…

Nelson P R, Bohanon H R, Wilson R K, Conrad F W, Mickens B, Taylor W D, Huza M A, Cox G H
Effects of ultraviolet germicidal irradiation of room air on airborne bacteria and mycobacteria.

As a result of the recent resurgence in tuberculosis (TB), there has been renewed interest inengineering controls to reduce the spread of TB and other…

Miller S L, Xu P, Peccia J, Fabian P, Hernandez M
Numerical determination of the effective depth for single-sided natural ventilation.

This paper describes a numerical method for the determination of the effective depth of fresh air distribution in rooms with single-sided natural…

Gan G
Comparisons of microorganism loading from two air filter materials during the first eight weeks of service life.

As part of an ongoing investigation on service life of air filtration material, a new type of airfiltration material (multi-layered polymer) was compared…

Kemp P C, Carlsson T, Nickelmann A, Neumeister-Kemp H-G
Displacement ventilation forming at different air flow rates.

The paper presents the results of the tests of two-zone airflow pattern forming in a room with displacement ventilation where various heat sources and…

Trzeciakiewicz Z, Popiolek Z, Mierzwinski S
Air filters for better indoor air quality.

The need to separate impurities from air or other gases has increased as regards both the degree of separation and the necessity to separate finer particles…

Gustavsson J
Research into thermal decomposition of indoor suspended bioparticles.

Airborne fungi in indoor air has the possibility to cause the air pollution problems of the fungally infection syndrome and the allergy syndrome, etc. in…

Moriya Y, Miyaji T, Yamayoshi T
A measurement of the thermal performance and air distribution of indoor sports ground using swirling flow type natural ventilation system.

This report describe the thermal performance and air distribution of a Kumamoto prefecturalindoor sports ground in Japan. The swirling flow type natural air…

Sakai K, Ishihara O, Nagano S
Does the air quality deteriorate during the use of air filters?

Emissions from dust collected in air filters have been investigated using in situ and chambermeasurements. Two air filters (class F6 and F8/9) were exposed…

Johansson J H P, Rossell L
Indoor air quality in museums and historical buildings in St Petersburg and in north-west region of Russia.

This presentation deals with the problem of achieving stable microclimate in old buildings ofSt Petersburg - such as churches, museums and palaces.…

Korkin V D
Indicators of natural ventilation effectiveness in twelve New Zealand schools.

Classrooms in New Zealand schools are mostly low rise buildings with natural ventilationdesigns, sized for summer cooling. This study has investigated…

Bassett M R, Gibson P
Destruction of VOC using photocatalyst under UC light irradiation - the influence of UV wavelength on mineralisation.

Avariety of gaseous pollutants in indoor air now are becoming an object to control. Thus, westudied a removal technique using TiO2 photocatalyst under 365…

Sakamoto K, Fukumuro T, Ishitani O, Kohno H
Experimental development of a natural controlled ventilation device.

The Building Components Technology Department of ICITE, the Central Institute forIndustrialization and Technology in Building of the Italian National…

Cavanna G, Daniotti B, Oliveri E, Varone G
Absorbability of contaminants from room air by snow cooling system.

Snow has already been used effectively as a cold energy resource in some heavy snowfall areasin Japan. As the surface of snow is covered with cold melting…

Iijima K, Kobiyama M, Hanaoka Y, Kawamura M, Toda H
A field experiment on indoor consistency distribution of combustion gas by ventilation performance of range hood.

In apartments of Korea, exhaust-only hood system is commonly installed for kitchen ventilation. However, as to resident's increasing complaints recently due…

Roh J W, Kim J T
Limits of natural ventilation through windows in office buildings.

Many HVAC systems built in the time between 1960 and 1980 have now reached the end oftheir lifetime and require retrofitting. When HVAC retrofits are…

Zeidler O, Fitzner K
A method for measuring air cleaner effectiveness.

Air cleaners are unitary devices that contain filtration media and fans. They are marketed for cleaning air in rooms. There is no current method for…

Bohanon H R, Nelson P R, Wilson R K